Installation
97
EN
Burner and nozzle characteristics tables
1
Natural Gas G20 – 20 mbar
AUX
R
UR
UR*
Rated heating capacity (kW)
1.1
3.1
3.3
6.0
Nozzle diameter (1/100 mm)
76
126
130
175
Reduced flow rate (W)
400
900
1600
1800
Primary air (mm)
1
1
0,5
1
2
Natural Gas G20 – 25 mbar
AUX
R
UR
UR*
Rated heating capacity (kW)
1.1
3.1
3.3
6.0
Nozzle diameter (1/100 mm)
73
120
123
165
Reduced flow rate (W)
400
900
1600
1800
Primary air (mm)
1
1
1
0.5
3
Natural gas G25/G25.3 - 25 mbar
AUX
R
UR
UR*
Rated heating capacity (kW)
1.1
3.0
3.3
6.0
Nozzle diameter (1/100 mm)
76
126
135
185
Reduced flow rate (W)
400
900
1600
1800
Primary air (mm)
1
1
0,5
0.5
4
Natural gas G25.1 – 25 mbar
AUX
R
UR
UR*
Rated heating capacity (kW)
1.1
3.1
3.3
6.0
Nozzle diameter (1/100 mm)
76
135
140
190
Reduced flow rate (W)
400
900
1600
1800
Primary air (mm)
1
1
1
0.5
5
Natural Gas G25 – 20 mbar
AUX
R
UR
UR*
Rated heating capacity (kW)
1.1
3.1
3.3
6.0
Nozzle diameter (1/100 mm)
82
140
145
200
Reduced flow rate (W)
400
900
1600
1800
Primary air (mm)
1
1
0.5
0.5
6
Natural gas G2.350 – 13 mbar
AUX
R
UR
UR*
Rated heating capacity (kW)
1.1
3.1
3.3
6.0
Nozzle diameter (1/100 mm)
100
175
180
280
Reduced flow rate (W)
400
900
1600
1800
Primary air (mm)
1
1
2
3
Summary of Contents for PM6621WLDR