Smeg PLDA21AC Instructions For Installation And Use Manual Download Page 5

 

Instructions for the installer 

 

 

2.2

 

Clearance above and around domestic appliances 

Extract from AGA601 

 

 

REQUIREMENTS 

1

 

Overhead clearances – (Measurement A

 

Range hoods

 and exhaust fans shall be installed in accordance with the 

manufacturer’s instructions. However, in no case shall the clearance 
between the highest part of the 

hob 

of the cooking 

appliance

 and a 

range 

hood

 be less than 600 mm or, for an overhead exhaust fan, 750 mm

Any other downward facing 

combustible surface

 less than 600 mm 

above the highest part of the 

hob

 shall be protected for the full width and 

depth of the cooking surface area in accordance with Clause 5.12.1.2. 
However, in no case shall this clearance to any surface be less than 450 
mm

 
2

 

Side clearances – (Measurements B & C

Where  B, measured from the periphery of the nearest 

burner

 to any 

vertical 

combustible surface

, is less than 200 mm, the surface shall be 

protected in accordance with Clause 5.12.1.2 to a height C of not less 

Summary of Contents for PLDA21AC

Page 1: ...__ 16 8 PROBLEMS AND CAUSES ________________________________ 18 Thank you for choosing our product We advise you to read this manual carefully It contains all necessary instructions for maintaining un...

Page 2: ...THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METH...

Page 3: ...REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN CARAVANS IT SHALL NOT BE USED AS A SPACE HEATER DO NOT SPRAY AEROSOLS...

Page 4: ...liance is classified as type Y in relation to fire hazards and can therefore be mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance...

Page 5: ...than 600 mm or for an overhead exhaust fan 750 mm Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of th...

Page 6: ...ilation Caution This hob may only be installed and operated in rooms permanently ventilated in accordance with current regulations For proper operation of a gas appliance it is essential for the air n...

Page 7: ...to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are place...

Page 8: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must 2 not be less than 0 75 mm 3 x 0 75 cable keeping in min...

Page 9: ...f functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps To change the nozzles proceed as described below 4 1 Replacement of nozzles on t...

Page 10: ...sumption mm MJ h Auxiliary 1 3 9 0 54 Semi rapid 2 6 3 0 68 Rapid 3 10 8 0 88 WOK 4 13 5 1 00 Burner NG 1 0 kPa Nominal gas Injector consumption mm MJ h Auxiliary 1 3 9 0 90 Semi rapid 2 7 5 1 20 Rapi...

Page 11: ...nob and turn the adjustment screw inside or at the side of the tap shaft depending on the model until there is a regular minimum flame Replace the knob and check burner flame stability rapidly turning...

Page 12: ...0 cm diameter must be used only on the central burner Each knob corresponds to the burner indicated The appliance is equipped with an electric lighting device To light the burners press and turn the k...

Page 13: ...aph 6 3 Diameter of containers When water reaches the boiling point lower the flame so that it doesn t overflow To avoid burns or damage to the hob all recipients or griddle plates must be placed with...

Page 14: ...ucts for steel and a wooden or plastic tool if necessary Rinse thoroughly and dry with a soft cloth or deerskin 7 2 Cleaning of cooking hob components The caps and flame spreader crowns are extractabl...

Page 15: ...n and free of obstacles and that the burners rest firmly on their supports Gas connection the gas connection must be checked periodically Flexible pipes if a flexible pipe is used it must be inspected...

Page 16: ...h bright yellow tips Black deposits on the bottom of the pans Defect of comburent air or incorrect injectors Call Service Center The flame is very short and noisy The flame moves away from the burner...

Reviews: