Smeg PGFU36X Manual Download Page 4

Instructions for the Installer

6

3. POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS

NOTE:

The following operation requires building and/or carpentry work and must therefore be carried

out by a competent technician.
Installation can be carried out on various material, such as masonry, metal, solid wood, plastic laminated
wood etc. As long as they are heat resistant (T = 90°C - 194° F).
Observe all governing codes and ordinances. Do not obstruct flow or combustion and ventilation air.

-

It is the installer’s responsibility to comply with installations guidelines specified on the model/serial
rating plate. The model/serial rating plate is located on the underside of the cooktop burner box.

-

The cooktop should be installed in a location away from strong draft areas, such as windows, doors

and strong heating vents or fans.

-

All openings in the wall or floor where cooktops is to be installed must be sealed.

-

Appliance should not be installed with an air curtain ventilation system that blows air downward
toward the appliance, unless the ventilation system and appliance have been designed, tested in
accordance with ANSI Z21.1 and listed by an independent testing laboratory for combination use.

This type of ventilation system may cause ignition and combustion problems with the gas cooking

appliance resulting in personal injury or unintended operation.

-

Cabinet opening dimensions that are shown must be used. Given dimensions are minimum
clearances.

-

Grounded electrical supply is required. See “3.2 Electrical requirements” section. Proper gas supply
connection must be available. See “3.1 Gas supply requirements” section

To prevent accidents or ruining the mobile components of the appliance, the following steps must be

taken before performing the procedures described below:

1 Remove all packaging parts (e.g. crate, carton, polystyrene and metal hooks). Do not eliminate this

manual as it is an integral part of the appliance and it should be kept handy for easy reference
whenever needed.

2 Temporarily remove all removable parts from the cooktop that could fall and cause personal injury or

damage to objects (burners, crowns and flame caps) during the attachment procedures These parts
must be refitted before using the appliance.

The measurements supplied in the tables referring to the figure below must be followed when attaching

the appliance to the support structure.

Summary of Contents for PGFU36X

Page 1: ...g Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified engineer who is able to install commission and test the appliance ...

Page 2: ...rnment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not attempt to switch on any appliances Do not touch any e...

Page 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS ...

Page 4: ...d tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use This type of ventilation system may cause ignition and combustion problems with the gas cooking appliance resulting in personal injury or unintended operation Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required ...

Page 5: ...2 50 mm 2 50 mm 2 50 mm 35 15 16 914 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere within 6 15 2 cm from rear wall is recommended Grounded outlet Locate within 24 61 cm from the right rear corner of the cut out drawer ...

Page 6: ...d to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition 2 If local codes permit a flexible metal appliance connector with the new AGA or CSAcertified design 4 5 feet 1 2 1 5 m long 1 2 or 3 4 ...

Page 7: ...y closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an oven the gas pipe must not pass along the back of the oven as this may cause overheating 3 2 Electrical requirements WARNING ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet Do not cut or...

Page 8: ...NSI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the customer to have a properly polarized and grounded 3 prong outlet installed by a qualified electrician Copies of the standards listed above may be obtained from National Fire Protection Association ...

Page 9: ...O CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME Leak testing of the appliance shall be conducted according to the manufacturer s instructions The following procedures must be performed to adjust the gas supply pressure for LP operation of the cooktop 1 Unscrew cap A on the pressure regulator 2 Turn it to the part where LP is printed 3 Re tighten it and lock the pins in the slots provided 4 There is...

Page 10: ...to secure the hob to the supporting structure adjusting it until perfectly horizontal Carefully trim off the excess edge of the gasket A pic 2 The dimensions in picture 2 below refer to the distance between the hole and the inside edge of the gasket Do not fit the brackets shown in pic 3 until the hob has been set in place 1 2 3 NOTE Use all of the brackets supplied with the appliance to fasten it...

Page 11: ...gasket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure regulator D and adaptator C and between pressure regulator D and pipe E 6 Before turning on the burners make sure that the flame spreader crowns and respective caps are properly fitted in their housing...

Page 12: ...d to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as and you have checked to ensure that all parts have been fitted properly 1 a spark must light on all burners when the knobs on the top are pressed 2 when each knob on the cooktop is pressed and turned to the low flame symbol the entire crown should light 3 lf burne...

Page 13: ...equipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...

Reviews: