background image

 

 

Instructions for the installer

 

 

32

 

 

4

 

FINAL OPERATIONS 

After carrying out the above adjustments, remount in reverse order to the 
instructions given in paragraph “3.1 Replacement of nozzles on the hob”. 

 

 

 

 

After adjustment to a different kind of gas from the one for which the 
appliance has been tested, replace the plate inside the storage 
compartment with one corresponding to the new kind of gas. The label is 
available from your nearest Authorised Assistance Centre. 

 

 

4.1

 

Regulation of minimum for town gas and natural gas 

 

Light the burner and set it at minimum position. 
Remove the knob and turn the regulation screw 
inside or next to the gas tap pin (depending on the 
model) until you get a suitable minimum flame. 
Replace the knob and check burner flame stability: 
(when you turn the knob quickly from maximum to 
minimum position, the flame should not go out).  
Repeat this operation for all the gas taps. 

 

 

4.2

 

Regulation of minimum for LPG 

To regulate the minimum for LPG, fully tighten the screw inside or next to 
the gas tap pin (depending on the model) in a clockwise direction. 
The diameters of the by-passes for each burner are given in table “3.2 
Burner and nozzle characteristics table”. 

 

4.3

 

Lubrication of gas taps 

 

 

With time it may happen that the gas taps get blocked and hard to turn. 
Clean them inside and re-grease them. 

This operation must be done 

by an authorised person.

 

Summary of Contents for PGF95-2

Page 1: ...MAINTENANCE ___________________________ 35 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these...

Page 2: ...VE THE PACKAGING MATERIALS UNATTENDED IN THE HOME ENVIRONMENT SEPARATE THE DIFFERENT WASTE MATERIALS FROM THE PACKAGING AND DELIVER THEM TO THE NEAREST COLLECTION CENTRE FOR RECYCLABLE WASTE REGULATIO...

Page 3: ...E APPLIANCE IS DESIGNED FOR USE BY ADULTS DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQ...

Page 4: ...1 figure to avoid damage from overheating Make sure there is a minimum of 750 mm between the gas rings and any shelf that may be installed directly above them Carefully position the gasket provided a...

Page 5: ...here is a minimum of 750 mm Fig 1 between the gas rings and any shelf that may be installed directly above them This type of appliance also requires a cut 3 mm deep in the work top with the dimensions...

Page 6: ...led surface Important Other types of installation will only be possible under the manufacturer s supervision Overall dimensions location of gas and electrical connection points all measures in mm Caut...

Page 7: ...y see detail B fig 5 The following figures show how to use the brackets IMPORTANT when installing the appliance above a cupboard a dividing shelf as shown above must be installed If installed above an...

Page 8: ...ar the appliance Do not use reducers adapters or shunts If the power cable is to be replaced the wire section on the new cable must not be less than 0 75 mm 2 3 x 0 75 cable bearing in mind that the e...

Page 9: ...to be blocked in any way The room must be suitably ventilated to avoid overheating or excess humidity produced by cooking after any prolonged use a window should be opened or the speed of any fans sho...

Page 10: ...s must not provoke stress of any kind on the appliance Connection may be made by using biconicaladapter D with insertion of gasket C supplied Connection with flexible steel pipe use only flexible stai...

Page 11: ...nged and the minimum flame adjusted on the gas taps To change the nozzles proceed as described below 3 1 Replacement of nozzles on the hob 1 Remove the grids and all the caps and flame spreader crowns...

Page 12: ...valves marked and shown in point 4 1 Regulation of minimum for natural gas Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter 1 100 mm Reduced flow rate W Auxiliary 1 1 05 72 35...

Page 13: ...d turn the regulation screw inside or next to the gas tap pin depending on the model until you get a suitable minimum flame Replace the knob and check burner flame stability when you turn the knob qui...

Page 14: ...iameter must be used only on the central burner A symbol next to each knob indicates the relative burner The device is fitted with electronic ignition Simply press and turn the knob counter clockwise...

Page 15: ...aph 5 3 Diameter of receptacles When water reaches boiling point lower the flame so that it does not boil over To avoid burns or damage to the worktop all receptacles or griddle plates must be placed...

Page 16: ...c scourers or sharp scrapers be used they will damage the surface Use normal non abrasive products for steel and a wooden or plastic tool if necessary Rinse thoroughly and dry with a soft cloth or cha...

Page 17: ...Instructions for the user 36 In models equipped with pan stands fit as shown in the figure taking care to position them exactly as shown Refer to the enlarged details in the figure below for guidance...

Reviews: