Smeg PGF75SCU3 User Manual Download Page 9

Instructions for the Installer

11

4. INSTALLING THE COOKTOP

1)

Remove the polystyrene support and lift the hob to extract it from
the side supports and the box.

2)

Connection to the gas mains may be made with a flexible metal
pipe and conforming to the provisions defined by current standard
regulations in force. USE A SOAPY SOLUTION TO CHECK FOR
PROPER TIGHTNESS.

NEVER USE A FLAME.

Leak testing of the appliance shall be conducted according to the
manufacturer’s instructions.

The following procedures must be performed to adjust the gas
supply pressure for LP operation of the cooktop:
1 Unscrew cap A on the pressure regulator
2 Turn it to the part where LP is printed
3 Re-tighten it and lock the pins in the slots provided.
4 There is an arrow printed on the back of the energy regulator.

The tip of the arrow indicates the end to be connected to the
cooktop connector.

Summary of Contents for PGF75SCU3

Page 1: ...Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be perfo...

Page 2: ...nment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do n...

Page 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Page 4: ...ooktops is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See 3 2 Electrical requi...

Page 5: ...2 50 mm 2 50 mm 2 50 mm 28 3 8 720 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere wi...

Page 6: ...to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas...

Page 7: ...closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an...

Page 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Page 9: ...CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME Leak testing of the appliance shall be conducted according to the manufacturer s instructions The following procedures must be performed to adjust the gas...

Page 10: ...o secure the hob to the supporting structure adjusting it until perfectly horizontal Carefully trim off the excess edge of the gasket A pic 2 The dimensions in picture 2 below refer to the distance be...

Page 11: ...asket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure re...

Page 12: ...to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as and you have checked to ensure that all parts have been fitted pr...

Page 13: ...quipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring e...