Instructions for the installer
3.2
Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31
30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flow rate
(W)
Flow rate
g/h G30
Flow rate
g/h G31
Auxiliary (1)
1.05
50
30 *
27/28 **
400
76
75
Semi rapid (2)
1.75
63
30 *
32/33 **
500
127
125
Ultra Rapid (3)
3.9
100
65 *
63/65 **
1600
284
279
*/**: diameters marked * and ** must be fitted respectively on valves marked * and
**shown in point "4.1 Adjusting the minimum setting for natural gas".
Burner
Rated
heating
capacity
(kW)
Natural gas – G20
20 mbar
Nozzle diameter
1/100 mm
Reduced flow rate
(W)
Auxiliary (1)
1.05
72
400
Semi rapid (2)
1.75
97
500
Ultra Rapid (3)
3.9
135
1600
3.3
Arrangement of burners on cooking hob
BURNERS
1.
Auxiliary
2.
Semi rapid
3.
Ultra rapid
29