Instructions for the installer 

 

13

 

 

3.1

 

Electrical connection 

 

 

Make sure that the voltage and capacity of the power line conform to the 
data shown on the plate located under the casing. Do not remove this 
plate for any reason.
 

 

 

The plug on the end of the supply cable and the wall socket must be the 
same type and conform to the current electrical system regulations. 
Check that the power line is adequately grounded. 

 

 

On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 3 mm, located in an easily accessible 
position near the unit. 

 

Do not use reducers, adapters or shunts. 

 

 

 

If the power cable is replaced, the wire section on the new cable must 
not be less than 0.75 mm

2

 (3 x 0.75 cable), keeping in mind that the end 

to be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has 
a maximum temperature of 90°C. Any replacement needed should be 
carried out by a specialised technician who should make the mains 
connections according to the following diagram. 
L = brown 
N = blue 

 = yellow-green

 

 

 

 

 

 

The manufacturer will not be liable

 

for any damage to persons or 

property caused by non-observance of the above instructions or deriving 
from the tampering of even a single part of the hob.

 

 

Summary of Contents for PGA95F3

Page 1: ...___ 19 8 PROBLEMS AND CAUSES ________________________________ 20 Thank you for choosing our product We advise you to read this manual carefully It contains all necessary instructions for maintaining u...

Page 2: ...PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING...

Page 3: ...N PLAY WITH THE HOB REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE THIS APPLIANCE IS DESIGNED FOR COOKING FOOD AND IT SHALL NOT BE USED AS A SPACE HEATER DO NOT SPRAY AEROSOL...

Page 4: ...the appliance and the wall as shown in the figure to avoid damage from overheating Make sure there is a minimum of 750 mm between the gas rings and any shelf 1 that may be installed directly above th...

Page 5: ...elf that may be installed directly above them This type of appliance also requires a cut 3 mm deep in the work top with the dimensions shown in figure 4 detail A figure 2 Before positioning the hob po...

Page 6: ...may exceed 125 degrees C To avoid a hazard under bench access must be restricted Refer to installation instruction IMPORTANT when installing the appliance above a cupboard a dividing shelf as shown a...

Page 7: ...ever in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or for an overhead exhaust fan 750 mm Any other downward facing co...

Page 8: ...art of the appliance where cooking normally takes place and does not include those parts of the appliance containing control knobs 3 For definition of hob see Clause 1 4 64 4 For definition of trivet...

Page 9: ...f hoods connected to a natural draught flue with certain efficiency or by means of forced aspiration An efficient aspiration system requires careful planning by a specialist capable of installing it r...

Page 10: ...sion to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are...

Page 11: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 0 75 mm 2 3 x 0 75 cable keeping in min...

Page 12: ...adjust the minimum flame on the gas taps For nozzle replacement and burner adjustment operate as described in the following paragraph 4 1 Replacement of nozzles on the hob This operation requires no p...

Page 13: ...Nominal gas consumption MJ h Injector mm Auxiliary 1 3 9 0 54 Semi rapid 2 6 3 0 68 WOK 4 13 5 1 00 Burner NG 1 0 kPa Nominal gas consumption MJ h Injector mm Auxiliary 1 3 9 0 90 Semi rapid 2 7 5 1...

Page 14: ...est Authorised Assistance Centre 5 1 Adjustment of minimum for natural gas Light the burner and take it to the minimum Remove the gas tap knob and turn the adjustment screw inside or at the side of th...

Page 15: ...rger than 28 cm diameter must be used only on the central burner Each knob corresponds to the burner indicated The appliance is equipped with an electric lighting device To light the burners press and...

Page 16: ...nt lower the flame so that it doesn t overflow To avoid burns or damage to the hob all recipients or griddle plates must be placed within the perimeter of the cooking hob When using fats or oils be ex...

Page 17: ...sponges or sharp scrapers they will damage the surface Use normal non abrasive products for steel and a wooden or plastic tool if necessary Rinse thoroughly and dry with a soft cloth or deerskin 7 2 C...

Page 18: ...o be cleaned and re greased this operation must be carried out by an authorised person 8 PROBLEMS AND CAUSES Each of the following cases is caused by an abnormal operation of the appliance and should...

Page 19: ......

Page 20: ...914772758 C...

Reviews: