Instructions for the installer
23
• Lift the hob top upwards.
10.2 Adjustment for LPG
Loosen screw
A
and push support
B
all the way. Using a a double head, remove
nozzle
C
and replace it with the appropriate nozzle, following the instructions in
the tables for the type of gas to be used. The nozzle tightening torque must be
no more than 3 Nm. Reposition support
B
so that nozzle
C
is covered perfectly.
Move the Venturi tube
D
to adjust the air flow until distance “X” is reached as
indicated in the table in paragraph “10.4 Primary air adjustment” and then
secure the tube by means of screw
A
. After the adjustments have been carried
out, restore the seals with sealing wax or equivalent material.