Instructions for the installer

 

 

 

25 

5.

 

Adapting to different types of gas 

 

 

 

 

 

Before performing any cleaning or maintenance work, detach the hob from the 
electrical socket.

 

 
The hob has been inspected for 

G20

 (2H) 

natural gas

 at a pressure of 20 mbar.  

For functioning with other types of gas the nozzles must be replaced and the primary 
air adjusted. 
To replace the nozzles and regulate the burners, you have to remove the top as 
described in the following paragraph. 

 

5.1

 

Removing the hob 

Remove all of the burner components by following the numerical sequence shown in 
the figure: 

 

remove all of the knobs (

1

) by pulling them upward; 

 

remove the grids (

2

), lifting up 

one of the two horizontal spokes

 

remove the burner caps (

3

) and flame caps (

4

); 

 

with wrench 

A

 (supplied), open the bayonet clamps on the burner rings by levering 

on guides 

B

 

after having removed all of the above-described components, raise the surface to 
access the burners and gas taps. 

 

 

 

Summary of Contents for P106

Page 1: ...rrangement of burners on hob ________________________________________28 5 9 Lubrication of gas taps _______________________________________________28 6 Description of controls ________________________...

Page 2: ...ER THE APPLIANCE HAS BEEN BUILT IN NEVER UNPLUG BY PULLING ON THE CABLE IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE COOKING HOB FOLLOWING THE INSTRUCTIONS BELOW SHOULD THE...

Page 3: ...the counter keeping a minimum distance of 50 mm from the rear border This unit may be set against walls that are higher than the hob as long as distance X see figure is maintained to prevent damage t...

Page 4: ...fer to the distances shown in the figure for the model to be installed keeping in mind that for both models the long front side has to skim the hole Secure the hob to the counter with brackets A suppl...

Page 5: ...to 3 mm located in an easily accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 0 75 mm2 3...

Page 6: ...ssure of 20 mbar For use with other types of gases see Section 5 Adapting to different types of gas The gas intake fitting is gas external threaded ISO 228 1 Connection with rigid copper pipe the conn...

Page 7: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 8: ...nd regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob Remove all of the burner components by following the numerical sequence shown in the fig...

Page 9: ...dium rapid 2 3 75 40 40 700 167 164 Large rapid 3 0 82 40 45 800 218 215 A 76 UR B 3 6 48 48 50 1000 261 257 diameters marked and must be fitted respectively on valves marked and shown inpoint 5 6 Reg...

Page 10: ...s set correctly 5 5 Reassembling the hob Follow the instructions given in paragraph 5 1 Removing the hob but in the reverse order When replacing the burner rings remember that they have to be tightene...

Page 11: ...el is inside the bag that contains the nozzles 5 8 Arrangement of burners on hob BURNERS 1 Auxiliary 2 Semi rapid 3 Medium rapid 4 Large rapid 5 UR If the flame of the UR burners have unstable flame t...

Page 12: ...lame is lit by pressing the knob and simultaneously turning it anticlockwise to the minimum flame symbol To adjust the flame turn the knob to the zone between maximum and minimum Turn off the flame by...

Page 13: ...device It may happen that the burner goes out when the knob is released In this case repeat the operation keeping the knob pressed down for a longer time If the burners should go out accidentally afte...

Page 14: ...aps In normal use of the hob the grids and burner caps normally get browned as a result of the high temperature For optimum cleaning remove the burner cap and lift up one of the horizontal spokes of t...

Reviews: