Instructions for the installer
43
8.1 Burner, nozzle and gas consumption characteristics
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.05
50
30
400
76
75
Rapid
3.0
85
45
800
218
214
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1.05
72
400
Rapid
3.0
115
800