11
EN
Filter alarm display:
After 30 hours of motor operation, the LEDs L1-L5
come on for 30’’ each time the motor is turned off.
After 120 hours of motor operation, the LEDs L1-L5
blink for 30’’ each time the motor is turned off.
To reset the alarm, press any one of the keys P1-P5 for
2” during alarm display.
!
ATTENTION
SAFETY SYSTEMS
In order to function correctly the product is equipped
with a series of safety devices which are also intended
to prevent any injury caused by inappropriate use.
In any case be very careful in using the product, above
all the parts in motion.
ALARM ON cONTROL (all models)
1.
All LEDs flashing: this means that the telescopic trol
-
ley is locked. Wait 30” and then press the UP/DOWN
button to release the trolley
2. UP/DOWN button LED flashing: this means that the
front panel of the filters is not closed properly. Reposi
-
tion it correctly.
MAINTENANcE
!
Before cleaning or maintenance cut the power.
cleaning the hood
WHEN TO CLEAN IT:
clean it at least every 2 months
to prevent the risk of fire.
EXTERNAL CLEANING: use a cloth moistened in luke-
warm water and neutral detergent (for painted hoods);
use specific products for steel, copper or brass hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked
in denatured ethyl alcohol.
WHAT NOT TO DO:
do not use abrasive or corrosi-
ve products (e.g. metal sponges, brushes, too hard
brushes, very aggressive detergents, etc.)
Cleaning the grease filters
WHEN TO CLEAN IT:
clean it at least every 2 months to
prevent the risk of fire.
HOW TO REMOVE THE FILTERS:
push the catch near
the handle towards the rear of the hood and pull the
filter downwards
HOW TO CLEAN THE FILTERS: hand wash or in the
dishwasher using a neutral detergent. If washing in the
dishwasher, possible discoloration of the filters does not
in any way compromise their functioning.
Replacing the charcoal filter (P)
(for filtering version only)
WHEN TO REPLACE IT:
replace it at least every 6
months.
HOW TO REMOVE IT: position the charcoal filter inside
the hood and fit the 2 filter clips (M).
MALFUNcTIONS
If something appears not to be working properly, do the
following simple checks before calling Technical Service:
• If the hood is not working:
Check that:
- The power has not been disconnected.
- A speed has been selected.
• If the hood performs inefficiently:
Check that:
- The motor speed selected is sufficient for the amount
of smoke and vapours released.
- The kitchen is sufficiently ventilated to allow air inta
-
ke.
- The charcoal filter is not worn (hood in filtering ver
-
sion).
• If the hood has turned off during normal functioning:
Check that:
- The power has not been disconnected.
- the omnipolar disconnection device has not tripped.
Components not provided with the product