background image

17

GB

USE

Control panel

L

Light

Switches the lighting system on and off.

S1 Led

Motor running led.
It flashes once after 100 working hours of the hood to indicate that the grease
filters need washing.
It flashes twice after 200 working hours to indicate that the grease filters need
washing and that the anti-odour charcoal filters, if any, need changing.

S2 Led

Intensive speed led.

M

Motor

Switches the extractor motor on and off at low speed. Used to provide a contin-

uos and silent air change in the presence of light cooking vapours.

When  the Hood is in ELC (Electronic Comfort) mode, the button will not
only turn the Ducting motor on, but will also disable this function.

V1 Speed

Reduces the operating speed.

When  the button is pressed with the Motor off, ELC (Electronic Comfort)
mode will be enabled again, giving a continuous, low noise flow of air.  Press
the button and hold it until Led S1 flashes slowly.

V2 Speed

Increases the operating speed.

V3 Intensive

Maximum speed, used for eliminating the highest cooking vapour emission.

Speed

Switches off automatically after 10 minutes operation. Can also be switched

off manually by pressing the button.

R

Receiver for

Optional Remote Control.

Remote Control

L

R

V1

V2

V3

M

S1

S2

Summary of Contents for KSEV97X

Page 1: ...Libretto Istruzioni Instruction Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de Instrucciones NL 38 DE 29 FR 20 GB 11 IT 2 ES 47 KSEV97X ...

Page 2: ...recommendations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 12 CHARACTERISTICS 13 INSTALLATION 14 USE 17 MAINTENANCE 18 ...

Page 3: ...of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave high na...

Page 4: ...y complete with Controls Light Blower Filters 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 10 1 Damper 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual ...

Page 5: ...he bracket Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 328 mm above the horizontal reference line Repeat this operation on the other si...

Page 6: ...re that the activated charcoal filters have been inserted Mounting the hood body Before attaching the hood body tighten the two screws Vr located on the hood body mounting points Hook the hood body onto the screws 12a Fully tighten support screws 12a Adjust screws Vr to level the hood body Connections DUCTED VERSION AIR EXHAUST SYSTEM In order to install the ducted version connect the hood to the ...

Page 7: ...r flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall making sure that they are well seated Fix the lower part laterally to the hood body using the 2 screws 12c 2 9 x 9 5 supplied 8a 2...

Page 8: ...of light cooking vapours When the Hood is in ELC Electronic Comfort mode the button will not only turn the Ducting motor on but will also disable this function V1 Speed Reduces the operating speed When the button is pressed with the Motor off ELC Electronic Comfort mode will be enabled again giving a continuous low noise flow of air Press the button and hold it until Led S1 flashes slowly V2 Speed...

Page 9: ...the filters The filters must be cleaned when led S1 flashes or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is vi...

Page 10: ...the metal grease filters Alarm signal activation On the recirulcation version extractor hood the filter saturation alarm is activated during installation or at a later date Switch off the lights and extractor motor Press button V2 for at least 10 seconds until the leds start to flash 2 flashes of the activated carbon odour filter saturation alarm led filter ACTIVATED 1 flash of the activated carbo...

Page 11: ...nes C E E 89 336 en matière de compatibilité électromagnétique et C E E 93 68 en matière de label CE DiesesGerätentsprichtfolgendenEG Richtlinien NiederspannungsrichtlinieEWG73 23hinsichtlichelektrischerSicherheit Richtlinie ElektromagnetischeVerträglichkeitEWG89 336undRichtlinieEWG93 68hinsichtlichderCE Kennzeichnung DitapparaatvoldoetaandeEuropeselaagspanningsnorm73 23 EEGinzakedeelektrischeveil...

Reviews: