USE

 

 
 

Control board 

Key Function 

Display

Switches the motor on/off at the latest  selected speed 

Indicates the selected speed 

Decreases the suction speed. 

Increases the suction speed. 

By pressing this key it is possible to start the intensive 
speed from any previously selected speed. This speed 
has been timed at 6 minutes. After that time the system 
activates automatically the latest selected speed. This 
function is recommended for cooking condition where 
vapours and odours need to be eliminated immediately 
and quickly. 

HI 

and the remaining time appear alternately.  

By pressing this key for about 5 seconds , with all the 
loads turned off (Motor and Lights), it is possible acti-
vated or deactivated the Charcoal Filter alarm. 

Show

 “FC” +

 (2

 

Flashes of a dot) – activated 

Show

 “FC” + 

(1

 

Flashes of a dot) – deactivated 

By pressing this key it is possible to set up the motor to 
a suction speed at 100 m

3

/h. During the intensive speed 

or the Delay-function this function cannot be activated. 

24 

appears and the spot down at the right side flash-

es once a second. 
By pressing the key the function is stopped. 

By pressing this key it is possible to set the delayed 
shutdown of the hood to 30 minutes. This function is 
suitable for a complete elimination of residual cooking 
odours. Functioning only when the motor is on(not 
during the 24H-function or intensive function) 

The suction speed and a dot flash once a second. 
By pressing the key the function is stopped 

Pressing and holding the button for 5 seconds enables 
the remote control.  
Pressing and holding the button for 5 seconds disables 
the remote control 

Show

 “IR” +

 (2

 

Flashes of a dot) – activated 

 
Show

 “IR” + 

(1

 

Flashes of a dot) – deactivated 

By pressing this key for about 3 seconds it is possible to 

reset 

the filter saturation alarm. 

Flash 

“FF” 

three

 

times. 

After 100 working hours a 

FG

 appears. Metal grease 

filters have to be washed. 
After 200 working hours 

FC 

appears.  Charcoal 

filters have to replaced. 

By pressing this key the intensity of the lighting system 
can be decreased. 

 

Switches on/off the lighting system at the maximum 
intensity. 

 

By pressing this key the intensity of the lighting system 
can be increases. 

 

Keyboard lock: it is possible to jam the keyboard when, for example, cleaning the glass. The motor and lights are 
switched off. By pressing for about 5 seconds the 

A

-key the keyboard block can be activated and “00” flash once or deac-

tivated “00” flash Twice. This function is confirmed by moving motor LEDS on display. 

Summary of Contents for KSEU912X

Page 1: ...Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEU912X ...

Page 2: ...EN 2 2 INDEX WARNINGS AND REQUIREMENTS 3 RECOMMENDATIONS AND SUGGESTIONS 6 DIMENSIONS and MAIN PARTS 7 INSTALLATION 8 USE 11 CARE 12 ...

Page 3: ...ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured H...

Page 4: ...cy Massachusetts 02269 This appliance should be connected directly to the fused disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the ap pliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When m...

Page 5: ...he American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors W A R N I N G Electrical ground is required on this rangehood If cold water pipe is interrupted by plastic nonmetallic gaskets or ...

Page 6: ...e kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The range hood has been designed exclusively for domestic use to eliminate kitchen odors Never use the hood for purposes other than for which it has ben designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the...

Page 7: ...Aria 8b 1 Left Air Outlet Grill Aria 10 1 Damper 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs if supplied 12a 6 Screws 3 16 x 1 3 4 12c 6 Screws 1 8 x 3 8 Q ty Documentation 1 Instruction Manual 5 1 8 2 7 16 35 3 8 12 3 1 2 12 1 2 21 1 4 2 3 8 10 5 8 19 5 16 Min 35 Max 38 1 8 11 12a ...

Page 8: ...on the wall as shown at X below the first bracket X height of the up per chimney section supplied aligning the center notch with the vertical line Mark the wall at the centers of the holes in the bracket Mark a reference point as indicated at 4 9 16 from the vertical reference line and 13 3 8 above the horizontal reference line Repeat this operation on the other side Drill ø 5 16 holes at all the ...

Page 9: ...T SYSTEM When installing the ducted version connect the hood to the chimney using a rigid 6 duct Install the damper 10 ø 6 Fix the duct in position using sufficient pipe clamps not sup plied DUCTLESS VERSION AIR OUTLET Push fit connection 15 onto the hood body outlet Insert the connection extension pieces laterally 14 1 in connec tion 15 Make sure that the outlet of the extension pieces 14 1 is ho...

Page 10: ...exhaust chimney Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seat ed Secure the sides to the brackets using the 4 screws 12c sup plied Lower exhaust chimney Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure that they are well seated Fix the lower part laterally to the hood...

Page 11: ...sible to set the delayed shutdown of the hood to 30 minutes This function is suitable for a complete elimination of residual cooking odours Functioning only when the motor is on not during the 24H function or intensive function The suction speed and a dot flash once a second By pressing the key the function is stopped Pressing and holding the button for 5 seconds enables the remote control Pressin...

Page 12: ...e of the hood Alarm reset Press the G key for at least 3 seconds See Use Paragraph Cleaning Remove the filters one at a time supporting them with one hand and turning the safety knobs pull and turn Wash the filters Pay attention not to bend them Make sure that filters are completely dry before putting them into their seat Place the filters again into their seats and make sure that the handle of th...

Page 13: ...flash once and show FC charcoal filter saturation alarm DEACTIVATED SUBSTITUTION OF THE CHARCOAL FILTER Alarm reset Switch off the motor and the lighting system Press the G key for at least 3 seconds See Use Paragraph Substitution of the filter Remove the metal grease filters Remove the charcoal filter as indicated in the picture Place the filter again into its seat Place again the metal grease fi...

Reviews: