Smeg KSEG52 Instruction On Mounting And Use Manual Download Page 6

11

Installation

These minimum distances between hobs and
grease filter must be observed:
Minimum 650 mm - electric hobs
Minimum 750 mm - gas or mixed hobs.

Electric connection (Not for UK)

Before completing any connection, make sure
the house voltage corresponds with the voltage
indicated on the label affixed inside the hood
It is advisable to call a qualified technician to
make the electrical connection.

Appliance fitted with plug.

Connect it to a socket which conforms with
current regulations.
If you intend to connect it directly to the electric
mains, remove the plug and fit an approved
bipolar switch with a minimum contact opening
of no less than 3mm.
If the plug is not accessible once it has been
inserted in the socket, it will however be
necessary to fit an approved bipolar switch with
a minimum contact opening of no less than
3mm.

Appliance without plug

Fit an approved plug or an approved bipolar
switch with a minimum contact opening of not
less than 3mm.

The manufacturers are not liable for any
problems caused by the user’s failure to
observer the above instructions.

GB

According the cooker hood you own:
Lamp 40W max (E14) or Neon lamp 14W
max or PL lamp 11W max (model with 1 PL
lamp) or PL lamp 9W max (model with two
PL lamps)

4. Reclose the protective shield for the lamp.
Before calling for repair service because the
hood fails to light up, make sure the lamps are
well inserted.

Warning!

— The hood cannot be connected to flues of

other appliances that run on energy sources
other than electricity.

— When the hood is used at the same time of

other appliances that run on energy sources
other than electricity, provision must be
made for an adequate supply of air.

— No food must be cooked flambé underneath

the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame under
the hood. When frying foods, never leave
the pan alone because the cooking oil could
flare up.

— Please, keep to the provisions of official

directives regarding the question of fume
discharge.

— The manufacturers refuse to accept any

responsibility for damage to the hood or its
catching on fire because of failure to observe
the above instructions.

Summary of Contents for KSEG52

Page 1: ... de montage et mode d emploi Instructions on mounting and use Montage en gebruiksaanwijzing Istruzioni di montaggio e d uso Instrucciones de montaye y para el uso Instalação e manutençao Vyxbherwvv gj exbfyjdrt v àrxgkefbfwvv D F I E P GB NL HEX ...

Page 2: ...2 Abb Fig afb 1 A A A A Abb Fig afb 2 2a 2b 2c 2d B B Abb Fig afb 3 1 2 3 ...

Page 3: ... F F Abb Fig afb 4 302 510 142 120 285 68 4 5 70 261 548 748 Abb Fig afb 5 748 710 302 302 119 285 68 4 5 70 160 150 150 119 Abb Fig afb 7 548 748 510 710 302 302 119 285 68 4 5 70 160 Abb Fig afb 6 Abb Fig afb 8 G ...

Page 4: ... B 3 F 4 5 C 6 C 7 7 6 C 6 C 6 C 5 C D D E E 1 2 3 4 5 6 7 Montage Installation Monteren Montaggio Fijación Montagem Ìîíòàæ A B C D E Demontage Démontage Dismounting Demonteren Smontaggio Desmontaje Desmontagem Äåìîíòàæ ...

Page 5: ...ease the grease filter support from the hood pullthereleasebuttonsB Fig 3 inwards To extract the metal grease filter from the support grill pull from right to left and extract the grease filter GB When washing the grease filter wash the support grate as well with warm soapy water Carry out the above steps in reverse order to put the filters back after having washed them making sure the entire extr...

Page 6: ...ot liable for any problems caused by the user s failure to observer the above instructions GB According the cooker hood you own Lamp 40W max E14 or Neon lamp 14W max or PL lamp 11W max model with 1 PL lamp or PL lamp 9W max model with two PL lamps 4 Reclose the protective shield for the lamp Before calling for repair service because the hood fails to light up make sure the lamps are well inserted ...

Page 7: ... AND YELLOW EARTH E 1 The GREEN AND YELLOW wire must be connected to the terminal in the plug which is marked with the letter F or by the Earth symbol or coloured green or green and yellow 2 The BLUE wire must be connected to the terminal which is marked with the letter N or coloured black 3 The BROWN wire must be connected to the terminal which is marked with the letter L or coloured red Systems ...

Page 8: ...LI1B5A Ed 02 99 ...

Reviews: