EN
1
14
Mounting the hood body
• Before attaching the hood body, tighten the two screws
Vr
lo-
cated on the hood body mounting points.
• Hook the hood body onto the screws
12a
.
• Fully tighten the support screws
12a
.
• Adjust the screws
Vr
to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
9
ø 120
ø 150
CONNECTIONS
• Make sure that the mains voltage is the same as the one indi-
cated on the technical rating plate inside the Hood.
• Connect the Hood to the Mains Power Supply, inserting a
bipolar switch with a contact aperture of at least 3 mm.
• Make the connection to the remote device and the earthing
connection in the Wiring Box provided, following the Wiring
Diagram supplied.
• Once electrical connections have been made, check that the
lights and motor are working properly.