EN
2
20
Mounting the hood body
• Remove the metal grease filters by turning the handles pro-
vided.
• Adjust the two screws
Vr
, on brackets
11a
, to a minimum.
• Hook the hood canopy onto the two brackets
11a.
• From inside the hood canopy, adjust the screws
Vr
to set the
Hood Canopy level.
• Tighten the safety screws
12a
.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
ø 150
9
ø 120
RECIRCULATION VERSION AIR OUTLET
• Insert the connection extension pieces laterally
14.1
in connec-
tion
15.
• Insert the Connector
15
into the Support bracket
7.3
and fix it
with a screw.
• Make sure that the outlet of the extension pieces
14.1
is hori-
zontally and vertically aligned with the chimney outlets.
• Connect the air outlet connection
15
to the hood body outlet
using either a flexible or rigid pipe ø 150 mm, the choice of
which is left to the installer.
• Ensure that the activated charcoal filters have been inserted.
15
ø 150
14.1
7.3