Smeg KIV90X Instruction Manual Download Page 12

EN

2
3

23

Activated Charcoal Filter (Recirculation Version) 

•  This cannot be washed or regenerated, and must be changed when all the command LEDs 

start to flash, or at least once every 4 months.  

Activating the alarm signal 
•  In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at 

a later date. 

•  Press and hold the Delay button (T4) on the keypad for 5 seconds and the following will be dis-

played: 

  •  Leds (L1-L2-L3) flash twice – Activated Charcoal Filter saturation alarm ACTIVATED. 
  •  Leds (L1-L2-L3) flash once – Activated Charcoal Filter saturation alarm DEACTI-

VATED. 

CHANGING THE ACTIVATED CHARCOAL FILTER

Resetting the alarm signal
•  Press any of the buttons except the Light button. 

Changing the Filter
•  Remove the Metal grease filters. 
•  Remove the saturated Activated Charcoal filter, as shown in 

the figure. 

•  Fit the new Filter, hooking it into place. 
•  Replace the Metal grease filters. 

Lighting

LIGHT REPLACEMENT 

20 W halogen light. 
•  Remove the snap-on lamp cover by levering it from under the 

metal ring, supporting it with one hand. 

•  Remove the halogen lamp from the lamp holder by pulling 

gently. 

•  Replace the lamp with a new one of the same type, making 

sure that you insert the two pins properly into the housings on 
the lamp holder. 

•  Replace the snap-on lamp cover.

Summary of Contents for KIV90X

Page 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es KIV90X...

Page 2: ...E CONSEILS ET SUGGESTIONS 24 CARACTERISTIQUES 25 INSTALLATION 27 UTILISATION 31 ENTRETIEN 32 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 34 CHARAKTERISTIKEN 35 MONTAGE 37 BEDIENUNG 41 WARTUNG 42 INHO...

Page 3: ...her than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it...

Page 4: ...EN 1 5 15 CHARACTERISTICS Dimensions 650 290 70 90 132 310 150 350 700 Min 780 Max 1070 36 Min 500mm Min 650mm...

Page 5: ...on flange 150 120 mm 14 1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps not included 26 2 Cable clamps 27 1 Finishing plug Ref Q ty Installation Compone...

Page 6: ...ceilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power s...

Page 7: ...frame by turning it Make sure that the screws do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the...

Page 8: ...of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outle...

Page 9: ...rmed on the galva nized diffuser support as shown in fig 2 Position the finishing plug 27 over the housing in the diffuser support fixing it us ing a screw 12e 2 9 x 9 5 and applying the 2 cable clamp...

Page 10: ...cooking fumes it is de activated by pressing any one of the Speed buttons T1 T2 T3 It cannot be activated if the Delay function is in use If the filter saturation alarm is on this resets it On Flashi...

Page 11: ...ore frequently if use is particularly intensive Resetting the alarm signal Press any of the buttons except the Light button Cleaning the Filters Remove the Filters one at a time pushing them towards t...

Page 12: ...ated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press any of the buttons except the Light button Changing the Filter Remove the Met...

Reviews: