Motor OFF key/ Filters reset key
Power key/hood speed selection
Start timed intensive speed
Lights ON/OFF key
EN
7
The timed intensive function is that mode of service for which the hood, for a limited
time, works at its maximum capacity.
Activating the function is displayed by the LED located under the key flashing. When
the intensive speed timer has expired it returns to the third speed by default.
KEY
FUNCTION
DISPLAY
A
SWITCH THE SUCTION MOTOR ON / OFF.
DISPLAYS THE SET SPEED
B
DECREASE THE OPERATING SPEED
DISPLAYS THE SET SPEED
C
INCREASE THE OPERATING SPEED
START TIMED INTENSIVE SPEED
DISPLAYS THE SET SPEED
FLASHING TIMED INTENSIVE
SPEED
D
TURN THE LIGHTING SYSTEM ON AND OFF
F
ENABLES THE AUTOMATIC SHUTDOWN DELAY OF 15'
FLASHES
1-DIGIT CAPACITIVE PUSHBUTTON BOARD:
SOFT TOUCH ELECTRONIC PUSHBUTTON BOARD:
-
TIMED AUTO POWER OFF
: By pressing one of the motor speed keys (2-3), twice,
you will activate the function "Timed Auto Power Off" which turns off both lights and hood
motor after 10 mins. Activating this function is demonstrated by the LED immediately
above the pressed button flashing.
-
FILTER CLEANING SIGNAL
: the simultaneous flashing of the 4 LEDs, (programmed
to run every 200h of operation), is to indicate the need to clean /replace the filters.
By pressing the OFF button
, the 200h time can be reset. N.B. Accidentally
pressing the OFF
button before the 200h does not result in the filter being
reset in the filter cleaning memory. It is good practice to clean the grease filters
and replace the active carbon filters every 200h of operation.
OPTIONAL FUNCTIONS:
Summary of Contents for KI90XE
Page 23: ...11 UE 2012 19 2014 14 49 26 RAEE 2 400 25...
Page 25: ...8 4...
Page 26: ...7 LED A D l B C D F 15 1 SOFT TOUCH OFF OFF 1 2 3 10 LED 100 LED 4 200 OFF 200 OFF 200 200...
Page 27: ...6 10 2 A B C D HI 5 E 24H 10 24 5 B EF 5 EF F 30 G 3 FF 100 EF 200 H 1 L 5 D...
Page 28: ...A B A B 5 15 3 3 ON OFF OFF 0 ON 3 2 1 ON OFF OFF 1 0 ON OFF OFF...
Page 29: ...L2 L1 K Z Z L L Z 4 8 Smeg 6 R1 R1 R2 150 7 K Z K L 3 5 6 7...
Page 30: ...150 3 1 650 1 1 2 2 2 2 3 5 L1 3 3 4 4 5 5 6 6 L2 7 7 3 2 8 8 L2 150 120 8 10 5 4 4 1 2 4 3...
Page 31: ...2 120...
Page 32: ...1 Smeg 650 120 8...
Page 122: ...1 Smeg I 650 120...
Page 123: ...2 8 120...
Page 125: ...Fig 5 Fig 6 Fig 7 L2 L1 K Z Z L L Z 4 8 Smeg 6 R2 R1 R1 D 150 7 K Z L K 3...
Page 126: ...A ON OFF B 0 1 2 3 ON OFF OFF A ON OFF 0 1 B OFF A B A B 5 15 B 3 3 B...
Page 127: ...6 2 DIGIT 10 A B C D HI 5 E 24H 10 24 5 5 EF EF F 30 G 3 FF 100 EF 200 H 1 L 5 D...
Page 128: ...7 LED A B C D F 15 1 DIGIT SOFT TOUCH OFF ON OFF 2 3 10 4 200 OFF 200 OFF 200 200 200...
Page 129: ...8 4...
Page 130: ...9 90 B C a 1 EN60825 1 1994 A1 2002 A2 2001 439nm 7 b G4 20 12 ILCOS HSG C UB 20 12 G4...