Smeg KI120X Instruction Manual Download Page 11

EN

2
1

21

USE

L

T1

T2

T3

T4

L1

L2

L3

L4

Control panel 

Button

Function

Led

L 

Press briefly to turn the lighting system on and off. 

Press and hold for approx. 2 seconds to turn the lighting system 
on and off at reduced intensity. 

-

T1 

Turn the suction motor on and off at speed one.  

If the filter saturation alarm is on, this resets it. 

On. 

T2 

Turn the suction motor on at speed two.  

If the filter saturation alarm is on, this resets it. 

On. 

T3 

Press once to turn the suction motor on and off at speed three.  

Press again to activate intensive speed. This speed is timed to run 
for 10 minutes. At the end of this time the system will 
automatically return to the speed set before. 

Suitable to deal with maximum levels of cooking fumes, it is de-
activated by pressing any one of the Speed buttons (T1-T2-T3). 

It cannot be activated if the Delay function is in use. 

If the filter saturation alarm is on, this resets it. 

On.  

Flashing. 

T4

Activate automatic switch-off with a 30’ delay (Motor+Lights). 
Suitable to complete elimination of residual odours.  

Can be activated from any Speed, and is disabled by pressing the 
button again or turning the motor off.  

It cannot be activated if the Intensive function is in use. 

If the filter saturation alarm is on, this resets it. 

On. 

Warning: The working hours of the motor are counted for the purpose of signalling filter 
saturation.  
After 100 working hours all the LEDs (L1-L2-L3-L4) will light up and remain lit to indicate 
saturation of the metal grease filters.  
After 200 working hours all the LEDs (L1-L2-L3-L4) will light up and start to flash to indicate 
saturation of the activated charcoal filters. 

Summary of Contents for KI120X

Page 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es KI120X...

Page 2: ...E CONSEILS ET SUGGESTIONS 24 CARACTERISTIQUES 25 INSTALLATION 27 UTILISATION 31 ENTRETIEN 32 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 34 CHARAKTERISTIKEN 35 MONTAGE 37 BEDIENUNG 41 WARTUNG 42 INHO...

Page 3: ...3 3 NDICE CONSELHOS E SUGEST ES 64 CARACTER STICAS 65 INSTALA O 67 UTILIZA O 71 MANUTEN O 72 PT...

Page 4: ...r than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it d...

Page 5: ...EN 1 5 15 CHARACTERISTICS Dimensions Min 500mm Min 650mm 676 60 898 1198 max 1050 min 870 700 290 350 150 90 310 135...

Page 6: ...l 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells Optional 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 24 1 Junction box 25 Pipe clamps not included Ref Q...

Page 7: ...ceilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power s...

Page 8: ...ats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the...

Page 9: ...of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outle...

Page 10: ...e is correctly inserted in the socket placed on the side of the fan Connect the control connector Cmd Connect the lights connector Lux Place the connectors in the junction box 24 and close it using th...

Page 11: ...cooking fumes it is de activated by pressing any one of the Speed buttons T1 T2 T3 It cannot be activated if the Delay function is in use If the filter saturation alarm is on this resets it On Flashi...

Page 12: ...r more frequently if use is particularly intensive Resetting the alarm signal Press any of the buttons except the Light button Cleaning the Filters Remove the Filters one at a time supporting them wit...

Page 13: ...nce Activated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press any of the buttons except the Light button Changing the Filter Remov...

Reviews: