The cooker hood must be placed at a minimum distance of 50 cm

from the cooking plane for electric cookers and 75cm for gas or

mixed cookers.

Do  not  tile,  grout  or  silicone  this  appliance  to  the  wall.  Surface

mounting only.
The hood is equipped with a top air outlet 

B

 for discharge of fumes

to  the  outside  (

Ducting  version 

–  exhaust  pipe  and  pipe  fixing

clamps not provided).

Should it not be possible to discharge cooking fumes and vapour to

the outside, the hood can be used in the 

filter version

, fitting an

activated carbon filter and the deflector 

F

on the support (bracket) 

G

, fumes and vapours are recycled through

the top grille 

H

 by means of an exhaust pipe connected to the top air

outlet 

B

 and the connection ring mounted on the deflector 

F

 (exhaust

pipe and pipe fixing clamps not provided).

The models with no suction motor only operate in ducting mode, and

must be connected to an external suction device (not supplied).

Expansion wall plugs are provided to secure the hood to most types

of walls/ceilings. However, a qualified technician must verify suitability

of the materials in accordance with the type of wall/ceiling. The wall/

ceiling must be strong enough to take the weight of the hood.

Do not tile, grout or silicone this appliance to the wall. Surface

mounting only.

Do not fix chimney flue to furniture or fly over shelves unless the

chimney flue can be easily removed, in case maintenance is ever

required.

Installation - Fig. 5-6-7

Preliminary information for installing the hood

Assembling the deflector (Fig. 6 - 3 parts – only for filter version):

The three parts should be fixed with 2 screws, the deflector extension

is adjustable and should correspond to the width of the chimney flue

support, to which it is then fixed.

During electrical connection ensure the power supply is disconnected

at the domestic main switch.
1. Adjust  extension  of  the  hood  support  structure,  as  the  final

height of the hood depends on this, and remember that with

installation completed the hood must be at least 50 cm above the

cook-top  for  electric  cookers  and  75  cm  for  gas  or  mixed

cookers.

2. a. Fix the two sections of the structure using 8 screws.

b.  If  the  hood  is  provided  with  extensions  longer  than  the

minimum, fit the reinforcement bracket S to the frame, using 4

screws.

3. Place the ceiling hole diagram directly above the cook-top (the

center of the diagram must match the center of the cook-top and

the edges must be parallel to the sides of the cook-top – the side

of the diagram with the wording FRONT corresponds to the

control panel side).  Prepare the electrical connection.

4. Drill as shown (6 holes for 6 wall plugs – 4 plugs for fixture),

screw the outer screws leaving a space of about 1 cm. between

the screw head and the ceiling.

5. Fit an exhaust pipe inside the truss and connect it to the motor

compartment connection ring (exhaust pipe and fixing brackets

are not supplied).

6. Hook the frame onto the 4 screws (see step 4).

CAUTION! The side of the truss with connection box corresponds

to the side of the control panel with hood assembled.

7. Tighten the 4 screws.

8. Insert and tighten another 2 screws in the remaining free holes

for secure fixing.

9. Carry out the electrical connection to the mains power supply,

only turn on the power supply upon completion of assembly.

10. Hook the hood onto the truss, ensuring it fits properly – to hook

the hood onto the truss partially tighten 4 screws (see also step

12).

11. Secure the hood to the truss using two screws; this will also help

center the two sections.

12. Tighten the 4 screws securing the truss to the hood.

13. For  extractor  versions  (13A),  connect  the  other  end  of  the

exhaust pipe to the flue.

For filter versions (13F), fit deflector F to the truss and secure it

to  the  bracket  supplied  using  4  screws,  then  connect  the

exhaust pipe to the connection ring located on the deflector.

14. Fit the nuts with fixing hooks supplied inside the top and bottom

sections of the flues at the rectangular slots. A total of 10 nuts

must be fitted.

15. Join the two top sections of the flue to cover the truss so that one

of the slots on the sections is situated on the same side of the

control panel and the other on the opposite side. Screw the two

sections  together  with  4  screws  (2  each  side-  see  the  plan

diagram for joining the two sections).

16. Fix the top flue assembly to the truss, near the ceiling, with two

screws (one each side).

17. Carry out electrical connection of control panel and bulbs.

Warning!  Make  connections  taking  care  to  insert  the

connectors in the right way.

18. Join the two bottom sections of the flue covering the truss  using

6 screws (3 each side, see the plan diagram for joining the two

sections).

19. Insert  the  bottom  section  of  the  flue  in  its  seat  so  that  it

completely  covers  the  motor  compartment  and  electrical

connection box, then ensure it from inside the hood using two

screws.

20. Apply  the  2  tabs  (supplied)  to  cover  the  fixing  points  of  the

bottom flue (CAUTION! THE BOTTOM FLUE TABS ARE THE

NARROWER AND SHALLOWER ONES).

The wider and deeper tabs are those used for the top flue, and

must be cut to size.

21. Turn the mains power on again at the central electrical panel and

check for correct hood operation.

Electrical connection

The electrical tension must correspond to the tension noted on the

label placed inside the cooker hood. Connect the electrical plug,

where provided, to the an easily accessible outlet in conformity with

local standards in force.

Where an electrical plug is not provided (for direct connection to

electrical network) place a standards approved bipolar switch with

an aperture distance of not less than 3mm (accessible) from the

contacts.

Summary of Contents for KESI120X

Page 1: ...GB INSTRUCTION ON MOUNTING AND USE ...

Page 2: ...1 7 6 5 2 4 3 2 1 4 6 7 5 3 2 4 1 5 6 7 3 7 6 5 4 3 2 1 7 6 5 2 4 1 3 6 5 2 7 3 1 7 6 1 3 2 5 4 4 1A 1B 1C 1D 1F 1G 1H ...

Page 3: ...g g j h i g g f f1 f2 2 3 4A 4B 4C ...

Page 4: ...3 4 4 4 4 4 4 6 6 7 7 7 7 8 8 2a 2a 2a 5 7 9 10 10 10 10 11 11 14 5 273 273 244 214 190 6 12 2b 2a 2b S B 5 ...

Page 5: ...15 15 15 15 15 16 16 15 15 13A 15 14 H 13F F G 6 ...

Page 6: ...18 18 18 18 18 18 18 18 18 18 M 17 19 X X 20 20 19 17 7 ...

Page 7: ... 6 holes for 6 wall plugs 4 plugs for fixture screw the outer screws leaving a space of about 1 cm between the screw head and the ceiling 5 Fit an exhaust pipe inside the truss and connect it to the motor compartment connection ring exhaust pipe and fixing brackets are not supplied 6 Hook the frame onto the 4 screws see step 4 CAUTION Thesideofthetrusswithconnectionboxcorresponds to the side of th...

Page 8: ...oncentration of cooking fumes or odours is particularly strong for example when frying cooking fish etc The fast speed will run for about 5 minutesandthenreturntothespeedpreviouslysetautomatically 1 2 or 3 or switch off if no speed was selected T o turn off the fast speed before the end of the 5 minutes press button 1 or button 2 8 OFF lamp button 9 ON lamp button If the hood fails to operate corr...

Page 9: ...ed carbon into the frame h and fit the whole back into its housing j Onlyformodelwithelectroniccontrolpanel Once you have replaced the charcoal filter press button 1 see preceding page for about 3 seconds until you hear the acoustic signal beep LED 5 will now stop flashing Replacinglamps Fig 4 Warning Prior to touching the light bulbs ensure they are cooled down For models shown in Fig 1A 1 press ...

Page 10: ...LI2CVA Ed 04 04 ...

Reviews: