Smeg KEIV90 Instruction On Mounting And Use Manual Download Page 8

 

12 

long enough to reach the exterior (aspiration version) or 
the deflector (filtering version).  

10. Only for filtering version:

 mount deflector 

F

 onto the 

trellis and fix it with 4 screws to the apposite bracket and 
finally connect the discharge tube to the connection ring 
placed on the deflector.  

11.

  Connect the electricity to the domestic power. Power 

must be supplied only after the installation has been 
completed.  

12. 

Put the nuts equipped with fixing hooks inside the 
sections of the upper and lower flues in correspondence 
with the rectangular slots. A total of 14 nuts should be 
mounted.  

13. 

Couple the two upper sections of the flue to cover the 
trellis so that one of the slits present on the sections is 
placed on the same side of the command panel and the 
other on the opposite side. 

 

Screw the two sections up with 8 screws (4 per side – 
also see the plan diagram for coupling the two sections).  

14. 

Fix the upper flue set

 

to the trellis near the ceiling with 

two screws (one per side).  

15. 

Couple the two lower sections of the flue to cover the 
trellis using 6 screws (3 per side - also see the plan 
diagram for coupling the two sections).  

16. 

Insert the lower section of the flue into the apposite 
housing to cover the motor space and the electrical 
connection box completely and fix with two screws from 
inside the hood.   

17. 

Apply the 2 tabs (supplied) to cover the fixing points of 
the sections of the lower flue (ATTENTION! THE TABS 
FOR THE LOWER FLUE ARE RECOGNISABLE 
BECAUSE THEY ARE NARROWER AND LESS DEEP). 

 

The larger and deeper tabs are those to use for the upper 
flue and are to be cut to measure. 

18. 

Supply

 

the electrical power again acting on the 

central electrical panel and check the correct functioning of 
the hood.  

 

Description of the hood 

Fig. 1 
1. 

Control panel 

2.

 Grease filter 

3.

 Grease filter release handle 

4.

 Halogen lamp 

5.

 Vapour catcher 

6.

 Telescopic chimney 

7.

 Air outlet (used for filter version only) 

  

 

Operation 

Use the high suction speed in cases of concentrated kitchen 
vapours.  It is recommended that the cooker hood suction is 
switched on for 5 minutes prior to cooking and to leave in 
operation during cooking and for another 15 minutes 
approximately after terminating cooking.  

Control panel 

 

a. 

ON/OFF light switch 

b. 

Speed 1/OFF switch  

c. 

 2-speed selection 

d. 

3-speed selection  

 

Reviews: