EN 

9

 

WARNINGS - COMPONENTS 

 

WARNINGS  

This appliance has been designed for use as either an 

EXTRACTION

 (ducting to the outside) 

or 

RECIRCULATION

 (filtering) hood. The measurements contained on the drawings in this 

booklet refer to two models of cooker hood. Therefore, it is essential that you refer to the cor-
rect drawing when taking measurements for installation.  

-  The minimum distance between the cooking surface and the metal grease filters on the 

underside of the hood must be 650mm. 

-  This cooker hood must be installed in accordance with the installation instructions and 

all requirements must be adhered to. 

-  If the room where the cooker hood is to be used contains a fuel burning appliance such 

as a central heating boiler then its flue must be of the room sealed or balance flue type. 

-  If other types of flue or appliances are fitted ensure that there is an adequate supply of 

air to the room. 

-  When the range hood and appliance supplied with energy other than electricity are 

simultaneously in operation, the negative pressure in the room must not exceed 4 Pa 
(4x10

-5

 bar). 

-  The ducting system for this appliance must not be connected to any ventilation system 

which is being used for any other purpose. 

-  The ducting system for this appliance must not be connected to any existing ventilation 

system which is being used for any other purpose. 

-  Do not leave naked flames or carry out flambè cooking under this cooker hood. 
-  This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 

-  Children should be supervised to ensure that they do not play with the appliance  

CONNECTING THE POWER CABLE TO THE MAINS POWER SUPPLY 

Before installation, check that the mains voltage indicated on the rating plate inside the appli-
ance corresponds to the voltage available in your home. If the Hood is not fitted with a plug 
have a licensed electrician, fit the power cable with a plug of a type approved for the load indi-
cated on the rating plate; when connecting directly to the mains, insert an omni polar circuit 
breaker with a minimum contact aperture of 3mm and a size suitable for the load in question 
between the appliance and the mains supply, making sure it is of a type that complies with cur-
rent regulations. 

 
COMPONENTS 

 
  - 2 No Wall Brackets 

C

 

  - 1 No 150-120mm Ducting Spigot 

G

 

  - 1 No Air Outlet Connection

 H 

 (Optional) 

  - 2 No Charcoal Filters 

L

 (Optional) 

 

Summary of Contents for KD61X2

Page 1: ...ioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções Руководство по эксплуатации Brugsvejledning Bruksanvisning KD61X2 KD91X2 KDC61X2 KDC91X2 ...

Page 2: ...ALLATION 14 UTILISATION ENTRETIEN 15 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 16 HINWEIS KOMPONENTEN 17 MONTAGE 18 BEDIENUNG WARTUNG 19 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES 20 AANWIJZINGEN ONDERDELEN 21 INSTALLATIE 22 GEBRUIK ONDERHOUD 23 INDICE CONSEJOS Y SUGERENCIAS 24 ADVERTENCIAS COMPONENTES 25 INSTALACIÓN 26 USO MANTENIMIENTO 27 ÍNDICE CONSELHOS E SUGESTÕES 28 ADVERTÊNCIAS COMPONENTES 29 ...

Page 3: ...НОСТИ 33 УСТАНОВКА 34 ЭКСПЛУАТАЦИЯ ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ 35 INDHOLD RÅD OG ANVISNINGER 36 VIGTIGE ANVISNINGER KOMPONENTER 37 INSTALLATION 38 BRUG VEDLIGEHOLDELSE 39 INNEHÅLL REKOMMENDATIONER OCH TIPS 40 VARNINGAR KOMPONENTER 41 INSTALLATION 42 ANVÄNDING UNDERHÅLL 43 RU DK SE ...

Page 4: ...llationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom...

Page 5: ...or any other purpose The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose Do not leave naked flames or carry out flambè cooking under this cooker hood This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless ...

Page 6: ... ø 120 mm air exhaust connection insert the reducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not supplied Remove any activated charcoal filters RECIRCULATION FILTERED When the hood is fitted in the recirculation mode the Air Outlet Connection H should be fitted as illustrated in fig 6 Fit the optional charcoal filters by repeating the following operati...

Page 7: ... Slide the glass towards the side from which the pin has been removed until the opposite edge has been freed then pull gently downwards Replace the bults and fit the glass again by repeating the above operations in reverse order 2 Filters The metal grease filter should be cleaned every two months or more frequently if the hood is used consistently and can be cleaned in a dishwasher or by hand usin...

Page 8: ...X X1 J 1 2 C X2 H J 1 2 750 min 1140 max 600 700 900 290 590 min 15 H J X1 A B 275 180 X2 180 180 J C 1 2 3 4 5 G ...

Page 9: ...6 7 8 9 10 B H 11 1 0 1 0 2 3 L M L V1 V2 V3 S 0 1 MID MAX 0 1 T2 T1 L T3 H L L M ...