EN
6
speed timer has expired it returns to the third speed by default.
Control panel
2-DIGIT 10-KEY CAPACITIVE PUSHBUTTON BOARD:
Key
Function
Display
A
Turns the suction motor on / off.
Displays the set speed
B
Decreases the operation speed.
Displays the set speed
C
Increases the operation speed.
Displays the set speed
D
Activates the Intensive speed from any speed even with the
motor off, this speed is timed. At the end, the system returns
to the speed previously set. Suitable for dealing with the
maximum emissions of cooking fumes.
Displays alternately HI
Hold the button down for about 5 seconds, when all loads are
off (Motor + Light), to switch the keyboard lock On / Off.
"- -" Keyboard lock On.
E
24 H function
Activates the motor at the first speed and allows extraction for
10 minutes every hour.
It displays 24 and the point at the bottom
right flashes once a second, while the
motor is in operation. Press the key to
disable it.
Holding the button down for about 5 seconds when all loads
are off (Motor + Light), holding key "B" down during the
animation, the Active Carbon Filters Alarm switches On / Off.
Displays a rotary animation for 5
seconds. "EF" flashes twice in activation.
"EF" flashes once in deactivation.
F
Delay function
Enables the automatic shutdown delay of 30'. Suitable for
removing residual odours. Can be activated from any position.
You disable it by pressing the key or turning the motor off.
Displays the operating speed and the
point on the lower right flashes.
G
With the filter alarm in progress, pressing the key for about 3
seconds resets the alarm.
After the procedure, the signal
previously displayed turns off:
FF signals the need to wash the metallic
grease filters. The alarm comes on after
100 hours of actual operation of the
Hood.
EF signals the need to replace the active
carbon filters and the metallic grease
filters must also be washed. The alarm
comes on after 200 hours of actual
operation of the Hood.
H
Decreases the light intensity at each press of the Key in a cyclic
manner.
1
Turns the lighting system on and off at maximum intensity.
L
Increases the light intensity at each press of the Key in a cyclic
manner.
Summary of Contents for KD120XE
Page 10: ......
Page 14: ...EN 12...