Smeg KD120XE Instruction Booklet Download Page 7

EN

6

speed timer has expired it returns to the third speed by default.

Control panel 

 2-DIGIT 10-KEY CAPACITIVE PUSHBUTTON BOARD:

Key 

Function 

Display

A

Turns the suction motor on / off.

Displays the set speed

B

Decreases the operation speed. 

Displays the set speed

C

Increases the operation speed.

Displays the set speed

D

Activates the Intensive speed from any speed even with the 

motor off, this speed is timed. At the end, the system returns 

to the speed previously set. Suitable for dealing with the 

maximum emissions of cooking fumes. 

Displays alternately HI

Hold the button down for about 5 seconds, when all loads are 

off (Motor + Light), to switch the keyboard lock On / Off.

"- -" Keyboard lock On.

E

24 H function

Activates the motor at the first speed and allows extraction for 

10 minutes every hour.

It displays 24 and the point at the bottom 

right flashes once a second, while the 

motor is in operation. Press the key to 

disable it.

Holding the button down for about 5 seconds when all loads 

are off (Motor + Light), holding key "B" down during the 

animation, the Active Carbon Filters Alarm switches On / Off.

Displays a rotary animation for 5 

seconds. "EF" flashes twice in activation.  

"EF" flashes once in deactivation.

F

Delay function

Enables the automatic shutdown delay of 30'. Suitable for 

removing residual odours.  Can be activated from any position. 

You disable it by pressing the key or turning the motor off.

Displays the operating speed and the 

point on the lower right flashes.

G

With the filter alarm in progress, pressing the key for about 3 

seconds resets the alarm.

After the procedure, the signal 

previously displayed turns off: 

FF  signals the need to wash the metallic 

grease filters. The alarm comes on after 

100 hours of actual operation of the 

Hood. 

EF  signals the need to replace the active 

carbon filters and the metallic grease 

filters must also be washed. The alarm 

comes on after 200 hours of actual 

operation of the Hood. 

H

Decreases the light intensity at each press of the Key in a cyclic 

manner. 

1

Turns the lighting system on and off at maximum intensity. 

L

Increases the light intensity at each press of the Key in a cyclic 

manner. 

Summary of Contents for KD120XE

Page 1: ...ng DA Manual de instrucciones ES Instrukcja PL Manual de lnstru es PT Instructiehandleiding NL Bruksanvisning NO RU Instruktionshandbo SV Ohjekirja FI Questo manuale d istruzione fornito da trovaprezz...

Page 2: ...tracted air must not be conveyed in a duct used to conduct fumes from appliances powered by gas or other fuel Connect the outlet for the air extracted by the hood to fumes discharge ducts with a suita...

Page 3: ...t supervision THE MANUFACTURER DECLINES ALL RESPONSIBILITY IF THE ABOVE INDICATIONS ARE NOT FOLLOWED USE This appliance was designed to be used as an EXTRACTION extraction of air to the outside or FIL...

Page 4: ...hood in the holes L1 Fig 4 3 Remove the grease filters and position the hood on the wall and mark the reference position for the holes to anchor the relative fixing system 4 Drill the 2 holes previou...

Page 5: ...of diameter D 150mm FLUE ASSEMBLY fig 6 Position the flue bracket K to the required top limit Mark the two holes on the wall to fix the bracket Drill and fix the bracket with the supplied expansion pl...

Page 6: ...rt cooking and to keep it on for at least 15min after you have finished cooking or until steam and odours have completely disappeared To start the hood identify the command type of the hood and then f...

Page 7: ...s when all loads are off Motor Light holding key B down during the animation the Active Carbon Filters Alarm switches On Off Displays a rotary animation for 5 seconds EF flashes twice in activation EF...

Page 8: ...splayed by the LED located under the key flashing When Keyboard lock On CONTROL PANEL KEY FUNCTION DISPLAY A SWITCH THE SUCTION MOTOR ON OFF DISPLAYS THE SET SPEED B DECREASE THE OPERATING SPEED DISPL...

Page 9: ...e product It is advisable to clean the hood by always rubbing the steel in the direction of the surface finish TIMED AUTO POWER OFF By pressing one of the motor speed keys 2 3 twice you will activate...

Page 10: ......

Page 11: ...ilters are capable of retaining odours until the carbon reaches saturation level They cannot be washed and they are not renewable therefore it is recommended to replace them at least every six months...

Page 12: ...n lamps a WITH LED LIGHTS The LED lights guarantee a significant number of hours of operation Should it be replace due to being worn or faulty the entire spotlight must be replaced In this case contac...

Page 13: ...rate collection of waste electrical and electronic equipment As an alternative to autonomous disposal the device you want to dispose of can be given back to the retailer at the time of purchasing new...

Page 14: ...EN 12...

Reviews: