Smeg KCVB9SG Instruction Manual Download Page 6

EN 

 

 

 

Operating Features 
Keypad with 10 touch b 2 digit d IR-RX 

 

Buttons from left to right: 

 

• 

MOTOR ON/OFF 

Starts and stops the blower motor. The display shows the current speed  
setting. 
• 

SPEED – 

Reduces motor speed: V4 

→ V3 → V2 → V1

 

 

• 

SPEED + 

Increases motor speed: V1 

→ V2 → V3 → V4

 

 

• 

BOOST-SPEED MODE 

Enables BOOST-SPEED mode from any motor speed or when motor is 
off. To disable BOOST-SPEED, press the button again and stop the motor. 
BOOST-SPEED mode is set to operate for 10 minutes: during which the 
display alternatively shows 

HI 

and the remaining time and the dot at the 

bottom right flashes every second.

 

After 10 minutes the system automatically reverts to the previous speed 
setting. 

 

• 

24H AIR CHANGE 

Starts the blower motor at a speed that provides a flow rate of about 100 
m3/h. When 24h AIR CHANGE is enabled the display shows 

24

. 24h AIR 

CHANGE cannot be enabled when either BOOST-SPEED or DELAY -OFF 
is enabled. 

 

• 

DELAY 

Enables and disables the hood’s complete shutdown (motor+lights) after 
30 minutes: during which the display alternatively shows the motor speed 
and the minutes remaining and the dot at the bottom right flashes every 
second. 

Summary of Contents for KCVB9SG

Page 1: ...EN Specific Instruction Manual ...

Page 2: ...EN Installation instructions ...

Page 3: ...EN Grease filter extraction instructions 1 Top glass extraction phases NB Extract the bottom glass in the same manner Top removable glass Bottom removable glass ...

Page 4: ...EN 2 Grease filter extraction To remove the metal grease filter follow the instructions carried in the General Instruction Booklet ...

Page 5: ...nal memory EEPROM for storing system settings and flags Optional analog digital input for sensor and or external control Phase cutting motor control SOFT START light switch turn the lights on gradually to guarantee better performance of electronic components Automatic sensing of mains frequency number 50 flashing on display 230 VAC 50 Hz mains number 60 flashing on display 230 VAC 60 Hz mains Soft...

Page 6: ...inutes during which the display alternatively shows HI and the remaining time and the dot at the bottom right flashes every second After 10 minutes the system automatically reverts to the previous speed setting 24H AIR CHANGE Starts the blower motor at a speed that provides a flow rate of about 100 m3 h When 24h AIR CHANGE is enabled the display shows 24 24h AIR CHANGE cannot be enabled when eithe...

Page 7: ...f there is a metal Filter sat alarm FF appears on the display after 100 h of operation If there is a CA filter alarm EF appears on the display after 200h of operation REDUCE LIGHT INTENSITY LIGHTS ON OFF Turns the hood lights on and off at maximum intensity The increase reduce buttons adjust the lights intensity by 4 steps excluding max intensity INCREASE LIGHT INTENSITY ...

Page 8: ...ngs appear on the display only when the blower motor is off Direct procedure for enabling disabling remote control Turn off the motor and the lights and make sure that no alarms are on filter saturation Press and hold the DELAY button for about 5s until tc flashes twice on the display meaning that the remote control has been enabled tc flashes once on the display meaning that the remote control ha...

Page 9: ...EN Press button 24 to enable disable the remote control receiver tc flashes twice on the display when the remote has been enabled and once when the remote control has been disabled ...

Reviews: