9
purchased this product.
Appliance designed, tested and manufactured according to:
• Safety: EN/IEC 60335
-1; EN/IEC 60335-2-31, EN/IEC
62233.
• Performance: EN/IEC 61591; ISO 5167
-1; ISO 5167-3; ISO
5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3;
ISO 3741; EN 50564; IEC 62301.
• EMC:
EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2;
EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a
correct use in order to reduce the environmental impact:
Switch ON the hood at minimum speed when you start
cooking and kept it running for few minutes after cooking is
finished. Increase the speed only in case of large amount of
smoke and vapor and use boost speed(s) only in extreme
situations. Replace the charcoal filter(s) when necessary to
maintain a good odor reduction efficiency. Clean the grease
filter(s) when necessary to maintain a good grease filter
efficiency. Use the maximum diameter of the ducting system
indicated in this manual to optimize efficiency and minimize
noise.
Use
The hood is designed to be used either for exhausting
or filter version
.
Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
1. Lights ON/OFF
2. Motor ON/OFF
When key
“2”
is pressed the motor passes to speed 1.
If the key is pressed during working, the hood passes to
OFF
state.
3. Speed decrease
When key
“3”
is pressed the speed decreases from 4
(intense) to 1.
4. Speed increase
When key
“4”
is pressed with the hood in
OFF
state, the
hood passes to speed 1.
If the key is pressed during working, the speed increases
from 1 to 4 (intense).
The intense speed is timed. The standa
rd timing is 5’, at
the end of which the hood sets at speed 2.
To deactivate the function before the end of the time,
press key
“3”
, the hood sets at speed 3, when key
“2”
is
pressed the hood turns off.
A signal on the display corresponds to each speed:
OFF: No signal
Speed 1:
1
Speed 2:
2
Speed 3:
3
Speed 4:
4
flashing
5. Display
Grease filter signalling
The grease filter is signalled by the display with number 1
flashing after 40 hours of use.
This means that the grease filter needs to be washed.
The signalling is visible with the hood in
ON
state.
To eliminate the grease filter signalling, press key
“2”
for
more than 3”, until it turns off.
The signalling can be eliminated with the hood in
ON
state.
Carbon filter signalling (only for filtering version)
The carbon filter is signalled by the display with number 2
flashing after 160 hours of use.
This means that the carbon filter installed must be replaced.
The signalling is visible with the hood in
ON
state.
To eliminate the carbon filter signalling, press key
“2”
for
more than 3”, until it turns off.
The signalling can be eliminated with the hood in
ON
state.
In case both filters are signalled at the same time, numbers 1
and 2 flash on the display alternately.
The signalling can be reset by carrying out the above-
described procedure twice.
First it resets the grease filter signalling, then the carbon filter
signalling.
In the standard mode the carbon filter signalling is not active.
In case the filtering version hood is used, it is necessary to
enable the carbon filter signalling.
Activation of carbon filter signalling:
Set the hood to
OFF
and keep keys
“2”
and
“3”
pressed
contemporaneously for 3”.
Numbers 1 and 2 flash alternately for 2”.
Deactivation of carbon filter signalling:
Set the hood to
OFF
and keep keys
“2”
and
“3”
pressed
contemporaneously for 3”.
Number 1 flashes for 2”.
Temperature Alarm
The hood is equipped with a temperature sensor which
activates the motor at speed 3 in case the temperature in the
display zone is too high.
The alarm condition is indicated by the display with the letter
t
flashing.
This condition remains as such until the temperature falls
below the alarm threshold.
This mode can be quit by pressing key
“2”
,
“3”
or
“4”
.
Every 30” the sensor checks the ambient tempera
ture of the
display zone.
Summary of Contents for KCH62X
Page 2: ......
Page 3: ...2x 6x 5x45 mm 6x 8 2x 2x 3 5x9 5 mm 1x 1x 1x 1x 2x 3 5x5 mm 2x 1x 120 mm 125 mm 150 mm 1x...
Page 4: ......
Page 5: ...1 1 x 8mm 2 3 4 5 5mm 2 x 5x45mm 4 x 8x40mm...
Page 6: ...6 2 x 8 x 40mm 2 x 5 x 45mm 5cm 1cm 16cm 16cm 8 6cm 7 8 2 x 8mm...
Page 7: ...9 X cm 1 2 3 4 10 11 12 2 x 5x45mm 1cm 3cm X 2cm V Hz V Hz...
Page 8: ...13 14 120 125mm 16 2x 3 5x9 5 mm 15 2x 150mm 150mm...
Page 9: ...2X 3 5x5 mm 17 19 20 18 x 2 1 2 4 3...
Page 58: ...51 RU 8...
Page 59: ...52 3...
Page 62: ...55 LED 10 90 15...
Page 63: ...4...
Page 64: ...3...
Page 65: ...2...
Page 66: ...1...
Page 67: ......
Page 68: ...LIB0176590 Ed 05 21...