5.2 Regulation for LPG
Loosen screw
A
and push support
B
all the way. Use a double head
wrench to remove nozzle
C
and assemble the suitable one,
following the instructions indicated in the reference charts, with
respect to the type of gas to use. The screwing torque of the nozzle
should never exceed
3 Nm
. Reposition support
B
so that nozzle
C
is covered perfectly.
Move the Venturi tube
D
to regulate the air flow until distance "
X
" is
reached indicated in the chart in paragraph "5.4 Regulation of
primary air” and then secure the tube by means of screw
A
. After
the regulations have been carried out, restore the seals with sealing
wax or equivalent material.
11
(*) By-pass value for valveless appliances.
Burner
Rated
heating
capacity
(2.55 kW)
LPG - G30/G31
28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100 mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary (1)
1.05
48
30
33 (*)
380
76
75
Semi-rapid (2)
1.65
62
30
33 (*)
380
120
118
Rapid (3)
2.55
76
37
40 (*)
650
185
182
Rapid (4)
2.55
76
37
40 (*)
650
185
182
Ultra rapid (5)
3.9
95
65
1600
283
279