Smeg GW0160 Technical Instructions Download Page 5

 

 

 

 

0160, 1160, 4060, 4190 

Power Connection Conversion instruction 

Page 5 - 9 

 

 

3

 

CONVERSION PROCEDURE 

 

 

WARNING  
Before performing any operation, disconnect the device from the electricity and water supplies and make sure that 
there is enough space in front of the device - at least 1m

2

 

ILLUSTRATION 

PROCEDURE 

   

 

1.

 

Remove the bottom door (or "bottom plinth”). Undo 
the screws at the sides which secure the bottom door. 

 

 

2.

 

Disconnect the earth wire fixed to the left-hand corner 
of the part and pull the door outward. 

 

 

3.

 

Remove the "drip guard". 
. Undo the fixing screws at the sides 
. Lift up the bottom edge of the guard and pull it 
outward 

 

 

 

 

4.

 

This gives access to the components on the front cross-
bar;
 
in particular, you will need to work on: 
. power cable 
. fuse terminal clamps (for 1160 and 4060) 
. wires connecting the fuse terminal clamps to the 
power supply terminal board
 
. power supply terminal board connections 
. jumpers on voltage change terminal board 

Summary of Contents for GW0160

Page 1: ...e units with neutral 400V 3N 7 0kW can be converted on site to the corresponding 230V single phase version 230V 2 8kW The technical data plates of these devices state the two possible electrical conne...

Page 2: ...rable 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W FUSES 10 3x38 16 A ON POWER SUPPLY L1 L2 L3 In the table the characteristics of the power supply cable supplied with the configurable appliances produc...

Page 3: ...IRING DIAGRAM Refer to the latest electrical wiring diagram at www smegtech com The section of the diagram involved in this procedure is shown below 2 1 POWER SUPPLY 0160 1160 4060 Default configurati...

Page 4: ...0160 1160 4060 4190 Power Connection Conversion instruction Page 4 9 2 2 POWER SUPPLY 4190 Default configuration Configurable connection single phase 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W...

Page 5: ...sides which secure the bottom door 2 Disconnect the earth wire fixed to the left hand corner of the part and pull the door outward 3 Remove the drip guard Undo the fixing screws at the sides Lift up...

Page 6: ...mponents fuse terminal clamps power supply terminal board voltage change terminal board XCT configuration shown is 400 V 3N 7 The first component to be replaced or adapted by cutting the unused wires...

Page 7: ...the mains switch SZ Apply the same prescriptions as above Rear view 9 On WD4190 and GW4190 it is necessary to act on the mains switch TERMINALS Mains Switch maintaining in the case of single phase onl...

Page 8: ...n data plate 230V 1N single phase 230V wiring side L1 and L3 connected to the same terminal clamp L1 L2 and N connect to the same terminal clamp 12 Move the jumpers on the voltage change terminal boar...

Page 9: ...e Use the technical application to check that the device s inputs and outputs function correctly Set the type of connection 3 three phase 1 single phase in the SET UP menu following the procedure prov...

Reviews: