background image

Instructions for the user 

 

 

35 

 

 

7

 

USING THE HOB 

 

   

Before turning on the burners, make sure that the burner rings, caps 

 

and grids have been fitted correctly. 
In the ultrarapid burner, notch 

must be aligned with pin 

B

 

Grid 

(where available) is intended for use with woks (Chinese pans). 

Adapter 

comes only with open grids models and is intended for use 

with small sized vessels.

 

 

   

 

 

 

   

 

 

7.1

 

Ignition of the burners 

 

   

 

 Raised indicators make for easier and clearer reading and use of the 

controls, each knob being connected to its corresponding burner by a 
rib. Setting corresponds to the elongated part of the knob or to the 
marking on it. 
 
(Only where applicable) 
Double-crown burners, controlled by two knobs, feature two ribs, a long 
one corresponding to the small inner burner and a short one to the 
outer burner. 
Double-crown burners comprise an auxiliary and a rapid burner, 
controlled by two different knobs which allow both burners to be used 
at the same time or to select one or the other as required. 

 

   

The device is fit with electronic ignition. Simply press and 
simultaneously turn the knob counter-clockwise on the low point flame 
symbol, until the burner is ignited. 

 

Concerning models with valves, push the knob for approximately 2 
seconds in order to keep the flame burning and to activate the safety 
device. 

 

The burner might go off when the knob is released. In this case repeat 
the aforesaid operation keeping the knob 
pressed for more than 2 seconds. 

 

   

Should the burners go off accidentally in the models with valves, a 

 

safety device will trip after approximately 20 seconds to block the gas 
outlet even if the cock is open.

 

 

 

 

 

Summary of Contents for GKC755

Page 1: ...USING THE HOB______________________________________________ 35 8 CLEANING AND MAINTENANCE_________________________________ 37 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICA...

Page 2: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Page 3: ...E PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN...

Page 4: ...is classified type Y as regards risks against fire and it can be set adjacent to walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to p...

Page 5: ...on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily re...

Page 6: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must 2 not be less than 1 0 mm 3 x 1 0 cable keeping in mind...

Page 7: ...been inspected for G25 2L 3B P at a pressure of 25 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 C...

Page 8: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 9: ...replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs th...

Page 10: ...lation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Rated LPG G30 G31 28 37 mbar Bu...

Page 11: ...e the primary air for natural gas as shown in the following table and in paragraph 5 4 Regulation of primary air After the regulations have been carried out restore the seals with sealing wax or equiv...

Page 12: ...iary 1 1 0 1 0 Semirapid 2 1 0 1 5 Rapid 3 0 5 1 5 Rapid large 4 1 5 10 0 Fish pan 7 1 5 2 5 Ultra rapid 5 1 5 2 5 Ultra rapid 8 1 5 2 5 Internal 1 0 6 0 Double crown 6 External 1 5 10 0 Internal 1 0...

Page 13: ...model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of...

Page 14: ...Semirapid 3 Rapid 4 Rapid large 5 Ultra rapid 6 Double crown 7 Fish pan 8 Ultra rapid 9 Double crown 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happe...

Page 15: ...a long one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which allow both...

Page 16: ...at 7 3 Diameter of the pans Burners min and max in cm Auxiliary 7 18 Semirapid 10 24 Rapid 12 24 Rapid large 14 26 Double crown 12 28 Ultrarapid 22 28 Fish burner Special oval shaped vessels 7 4 Using...

Page 17: ...ve the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoro...

Page 18: ...ater using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out In fact humidity residues inside the burner holes might impair burner...