![Smeg FD432PMNFE4 Instruction Booklet Download Page 23](http://html1.mh-extra.com/html/smeg/fd432pmnfe4/fd432pmnfe4_instruction-booklet_1303794023.webp)
EN -22-
SR – Set
value blink
on freezer
set value
screen
Freezer comp.
Not Cold enough
This caution will be
seen especially after
long term of power
failure
1. Do not freeze the
foods that are thaw
and use in short time
period.
2. Set the freezer
temperature to colder
values or set the
super freeze , until
the compartment
gets to normal
temperature.
3. Do not put fresh
food until this failure
is off.
SR – Set value
Blink on cooler
set value
screen
"Refrigerator
comp.
Not Cold enough"
Ideal temperature for
Ref. Compartment is
+4
o
C. If you see this
warning your foods
have risk of spoiling.
1. Set the refrigerator
temperature to colder
values or set the
super cooling mode
until the compartment
gets to normal
temperature.
2. Do not open the
door much until this
failure is off.
SR – Set value
blink on freezer
and cooler set
value screen
"not cold enough
Warning"
It is combination of
"not cool enough"
error for both of the
compartments.
You will see this
failure when first
starting the appliance.
It will be off after the
compartments gets
normal temperature
SR – Set value
blink on cooler
set value
screen
Refrigerator
comp. too Cold
The foods starts to
freeze because of
the too much cold
temperature
1. Check if the “Super
cooling mode” is on
2. Decrease
the refrigerator
temperature values
“--”
"Low voltage
Warning"
When the power
supply gets lower
than 170 V the
appliance gets to
steady position.
This is not a failure.
This prevents any
damages on the
compressor. This
warning will off after
the voltage gets
required level