INSTALLATION - 57
91477A185/C
e
The nozzles not provided are available at Authorised Service Centres.
Electrical connection
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
65 cm models (A)
and 75 cm models (B)
90 cm models (C)
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
5 LPG G30/31 - 30/37 mbar
AUX
R
UR-3c
UR
Rated heating capacity (kW)
1.10
3.10
3.30
6.0
Nozzle diameter (1/100 mm)
48
85
87
115
Reduced flow rate (W)
400
1100
1800
1800
Primary air (mm)
1.5
8
1.5
12
Rated flow rate G30 (g/h)
80
225
240
436
Rated flow rate G31 (g/h)
79
221
236
429
6 LPG G30/31 - 37 mbar
AUX
R
UR-3c
UR
Rated heating capacity (kW)
1.10
3.10
3.30
6.0
Nozzle diameter (1/100 mm)
48
80
82
110
Reduced flow rate (W)
450
1100
2000
1800
Primary air (mm)
1.5
10
2
12
Rated flow rate G30 (g/h)
80
225
240
436
Rated flow rate G31 (g/h)
79
221
236
429
7 Town gas G110 – 8 mbar
AUX
R
UR-3c
UR
Rated heating capacity (kW)
1.10
3.10
3.10
3.80
Nozzle diameter (1/100 mm)
132
250
250
310
Reduced flow rate (W)
400
900
1400
1400
Primary air (mm)
1
1
1.5
1.5
See General safety instructions.
220-240 V 1N~
3 x 1.5 mm ²
three-core cable
220-240 V / 380-415
V 2N~
6 x 1.5 mm ²
six-core cable
220-240 V
3 x 6 mm ²
three-core cable
220-240 V 3~
4 x 6 mm ²
four-core cable
The values indicated refer to the cross-
section of the internal conductor.
The aforementioned power cables are
sized taking into account the
coincidence factor (in compliance with
standard EN 60335-2-6).
Use the supplied jumper for each
connection, if any