Instructions for the installer
2.2
Electrical connection
Make sure the voltage and the cross-section of the power supply line
match the specifications indicated on the identification plate positioned in
the storage compartment.
Do not remove this plate for any reason.
The plug at the end of the power cable and the wall socket must be the
same type (conforming to regulations in force). Check that the power line
is adequately grounded. Do not use reducers, adapters or shunts.
Fit the power supply line with a multipolar cut-out device with a contact
opening gap equal to or greater than
3 mm
in an easily accessible
position close to the appliance.
The appliance has a terminal board on
its rear.
To access it, remove the back cover.
Make the electrical connection in
accordance with the wiring diagram
shown below.
Operation at 380-415V3N
~:
use a H05RR-F
or H05RN-F five-wire cable (cable of 5 x 1.5
mm2).
Operation at 380-415V2N~
:
use a H05RR-F
or H05RNF four-wire cable (cable of 4 x 2.5
mm2).
Operation at 220-240 V~:
use a H05RR-F /
H05RNF three-wire cable (cable of 3 x 6
mm2).
The cable end to be connected to the
appliance must be provided with a ground
wire (yellow-green) at least 20 mm longer.
The manufacturer cannot be held liable
for damage to persons or
things caused by failure to comply with the above requirements or by
tampering with any part of the appliance.
45