Installation
149
EN
The appliance can work in the following
modes:
Multifunction model
•
220-240 V 1N
~
3 x 1.5 mm²
three-core
cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
Connection with plug and socket
Make sure that the plug and socket are of
the same type.
Avoid using adapters and shunts as these
could cause overheating and a risk of
burns.
5.5 Instructions for the installer
• The plug must be accessible after
installation. Do not bend or trap the
power cable.
• The appliance must be installed
according to the installation diagrams.
• Do not try to unscrew or force the
threaded elbow of the fitting. You may
damage this part of the appliance, which
may void the manufacturer’s warranty.
• Use soap and water to check for gas
leaks on all connections.
DO NOT
use
naked flames to find leaks.
• Turn on all the burners separately and at
then all together to make sure that the
gas valve, burner and ignition are
working properly.
• Turn the burner knobs to the minimum
position and check that the flame is
stable for each individual burner and all
the burners together.
• If the appliance does not work correctly
after having carried out all the checks,
contact your local Authorised Service
Centre.
• Once the appliance has been installed,
please explain to the user how to use it
correctly.
For New Zealand only:
• If this cooking range is to be connected
to a new or upgraded electrical
installation, then it must be connected to
the supply by a supply cord fitted with:
- An appropriately rated plug that is
compatible with the socket-outlet fitted to
the final sub-circuit in the fixed wiring that
supplies this cooking range;
Or:
- An appropriately rated installation male
connector that is compatible with the
installation female connector fitted to the
final sub-circuit in the fixed wiring that
supplies this cooking range.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).
Summary of Contents for CPF9GMAN