Smeg CI2000-76 Manual Download Page 4

can  be  seen  when  the  motor  is  off  and  for  about  30  seconds.  To  reset  the  hour  counter,  keep  the  button  pressed 
for  2  seconds  while  the  alarm  can  be  seen.

 

Controls  shown  in  Fig.  12: 

 Button  A:  turns  the  lights  on/off;  every  30  hours  of  operation  the  corresponding 

pilot  lamp  (S)  comes  on  to  indicate  that  the  grease  filters  must be  cleaned;  every  120  hours  of  operation  the 
corresponding  pilot  lamp  (S)  flashes  to  indicate  that  the  grease  filters  must  be  cleaned  and  the  charcoal  filter 
replaced.  To  restart  the  hour  counter  (RESET),  hold  the  button  A  pressed  down  for  about  1”  (while  the  pilot  lamp 
S  is  on).

 

Button  B:  drives  the  motor  in  first speed  (the  corresponding  pilot  lamp  comes  on);  when  holding  it  down  for about

 

1”, the motor cuts out; when pressing the button a  second time (while the  pilot lamp is  on)  , the TIMER is activated 
and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).  Button  C:  drives  the  motor  in  second  speed  (the 
corresponding  pilot  lamp  comes  on);  when  pressing  the  button  a  second  time  (while  the  pilot  lamp  is  on)  ,  the 
TIMER  is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).  Button  D:  drives  the  motor  in  third 
speed  (the  corresponding  pilot  lamp  comes  on);  when  pressing  the  button  a  second  time  (while  the  pilot  lamp  is 
on)  ,  the  TIMER  is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).  Button  E:  drives  the  motor 
in  fourth  speed  (the  corresponding  pilot  lamp  comes  on);  when  pressing  the  button  a  second  time  (while  the  pilot 
lamp  is  on)  ,  the  TIMER  is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).

 

Controls  shown  in  Fig.  13: 

Button  A  =  light  switch.  Button  B  =  motor  ON/OFF  switch  –  speed  I.

 

Button  C  =  speed  II  switch;  pressed  a  second  time,  the  timer  is  activated  and  the  motor  turns  off  after  10’:  the 
relevant  LED  flashes  continuously.    Button  D  =  speed  III  switch;  the  timer  acts  as  for  switch  C.    Button  E  = 
speed  IV  switch;  the  timer  acts  as  for  switch  C.

 

When  all  the  LEDs  flash  together,  this  means  the  grease  filters  need  cleaning  (about  every  30  hours  of  operation). 
To  start  the  hour  count  again,  press  key  C  twice  (or  else  keys  D  or  E).

 

Pay  special  attention  to  the 

grease  filters

:    if  the  model  purchased  has  the  controls  shown  in  Figure  11: 

the  grease  filters  must  be  cleaned  approximately  once  every  30  hours  of  operation  (when  the  central  segment 
on  the  display  goes  on  or  starts blinking).  Wash  out  the  filter  using  a  neutral  soap.  Once  the  cleaned  filters  are 
reinstalled,  keep  button  R  (Reset)  pressed  for  two  seconds  to  reset  the  counter.  If  the  model  purchased  has  the 
controls  shown  in  Figure  12:  the  grease  filters  must  be  cleaned  approximately  once  every  30  hours  of  operation 
(when  the  light  button  lamp  comes  on)  -  Fig.  12S).   Wash  out  the  filter  using  a  neutral  soap.  Once  the  cleaned 
filters  are  reinstalled,  to reset  the  counter  hold  the  light  button  pressed  down  for  about  1”  (Fig.12A)  while  the 
corresponding  pilot  lamp  (S)  is  on.  If  the  model  purchased  has  the  controls  shown  in  Figure  13:  the  grease  filters 
must  be  cleaned  approximately  once  every  30  hours  of  operation  (when  all  the  LEDs  flash  together).  Wash  out 
the  filter  using  a  neutral  soap.  Once  the  cleaned  filters  are  reinstalled,  press  key  C  twice  (or  else  keys  D  or 
E)  to  reset  the  counter

 

Removing the  grease  filters

:  Remove  the  grease  filters  by  moving  fastener  B and  turning  the  filter  outwards

 

(Fig.5).

 

Replacing the charcoal filters: 

for filtering hoods, the charcoal filters must be replaced. If the model purchased 

has  the  controls  shown  in  Figure  11,  the  charcoal   filters  must  be  replaced  whenever  the  central  segment  of  the 
display  starts  blinking  (i.e.  every  120  hours  of  operation).  If  the  model  purchased  has  the  controls  shown  in 
Figure12,  the  charcoal  filters  must  be  replaced  each  time  the  light  button  (Fig.12S)  lamp  flashes  (i.e.  every  120 
hours  of  operation).  If  the  model  purchased  has  the  controls  shown  in  Figure  13,  the  charcoal    filters  must  be 
replaced  according  to  use:  on  the  average  once  every  6  months.

 

Removing the charcoal  filters

: before removing  the  charcoal filters, the grease filters  will  have to be removed 

by  moving  catch  B  and  turning  the  filter  outwards  (Fig.  5).  Then  remove  the  charcoal  filters  by  turning  until  they 
are  released  from  the  pins  (Fig.  14).

 

Lighting

:  to  remove  the  halogen  lamps,  turn  the  locknut  counter-clockwise  (Fig.  15).  Replace  with  the  same 

type  of lamp. 

CAUTION:  Do  not  handle glass  bulb with  bare  hands.

 

Reviews: