8 LPG G30/31
AUX
SR
R
UR2 (int+ext)
Rated heating capacity (kW)
1.0
1.75
2.9
4.2
Nozzle diameter (1/100 mm)
50
65
85
46+91
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1900
Rated flow rate G30 (g/h)
73
127
211
305
Rated flow rate G31 (g/h)
71
125
207
300
9 LPG G30/31
AUX
SR
R
UR2 (int+ext)
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
50
65
81
46+85
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
450
550
800
1900
Rated flow rate G30 (g/h)
73
131
211
305
Rated flow rate G31 (g/h)
71
129
207
300
10 LPG G30/31
AUX
SR
R
UR2 (int+ext)
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
43
58
74
43+70
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(H2)+(S1)
Reduced flow rate (W)
400
500
800
1900
Rated flow rate G30 (g/h)
73
131
211
305
Rated flow rate G31 (g/h)
71
129
207
300
11 Town gas G110
AUX
SR
R
UR2 (int+ext)
Rated heating capacity (kW)
1.0
1.8
2.8
3.8
Nozzle diameter (1/100 mm)
145
185
260
140+320
Pre-chamber (printed on nozzle)
/8
/2
/3
-
Reduced flow rate (W)
400
500
800
1400
12 Town gas G120
AUX
SR
R
UR2 (int+ext)
Rated heating capacity (kW)
1.1
1.8
2.9
3.8
Nozzle diameter (1/100 mm)
145
185
260
130+290
Pre-chamber (printed on nozzle)
/8
/2
/3
-
Reduced flow rate (W)
400
500
800
1400