4.3 Burner and nozzle characteristics table (80/90 cm. model);
Burner
Rated heating
capacity (kW)
LIQUID GAS – G30/G31
28/37 mbar
Nozzle
diameter 1/
100 mm
By-pass
1/100
mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.05
50
30
400
76
75
Semi rapid
1.8
65
33
500
131
129
Rapid
3.0
85
45
800
218
214
Ultra-rapid
4.0
100
65
1600
291
286
Maxi oven
4.6* / 5.2**
106* / 110**
62
1300
378
371
Burner
Rated heating
capacity
(kW)
TOWN GAS – G110
8 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Auxiliary
1.05
145 (/8)
400
Semi rapid
1.8
185 (/2)
500
Rapid
3.0
260 (/3)
800
Ultra-rapid
4.0
350 (/13)
1200
The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.
Burner
Rated heating
capacity
(kW)
NATURAL GAS – G20/G25
20/25 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Auxiliary
1.05
72
400
Semi rapid
1.8
97
500
Rapid
3.0
115
800
Ultra-rapid
4.0
135
1500
Maxi oven
4.6* / 5.2**
155* / 164**
1300