![Smeg B72MFX Instructions For Installation And Use Manual Download Page 22](http://html1.mh-extra.com/html/smeg/b72mfx/b72mfx_instructions-for-installation-and-use-manual_1303653022.webp)
Instructions for the installer
24
15.2
Burner and nozzle characteristics table
Rated
heating
Burner
LPG
–
G30/G31
28/37
mbar
capacity
(kW)
Nozzle
By-pass
Reduced
Flowrate
Flowrate
diameter
mm
flowrate
g/h G30
g/h G31
1/100 mm
1/100
(W)
Auxiliary
1.0
50
30
350
73
71
Semi rapid
1.75
65
33
450
127
125
Triple crown
3.2
91
65
1500
233
229
Rated
heating
Burner
NATURAL GAS –
G20
20
mbar
capacity
(kW)
Nozzle diameter
Reduced Flowrate
1/100 mm
(W)
Auxiliary
1.0
72
350
Semi rapid
1.75
97
450
Triple crown
3.2
125
1500
15.3
Arrangement of the burners on the hob
BURNERS
1.
Auxiliary
2.
Semi rapid
4.
Triple crown
Summary of Contents for B72MFX
Page 24: ...914772537 C ...