Instructions for the installer
8
3.1
Electrical connection
Make sure the voltage and the cross-section of the power supply line match the specifications
indicated on the identification plate positioned in the storage compartment.
Do not remove this plate for any reason.
If the appliance is connected to the power supply network by means of a fixed connection, install a
multipolar cut-out device on the power supply line, in compliance with installation regulations, located
near the appliance and in an easily reachable position.
Connection to the power supply network may be fixed or with a plug and socket. In the latter case
the plug and socket must be suitable for the cable employed and conform to the regulations in force.
Regardless of the type of connection, the appliance must be earthed. Before connection, make sure
that the power supply line is suitably earthed. Avoid use of adapters and shunts.
1 - For operation on 220-240V
∼
:
use a H05V2V2-F type three-
core cable (3 x 1.5 mm
2
).
The end to be connected to the appliance must have an earth
wire (yellow-green) at least 20 mm longer than the others.
WARNING: THE VALUES INDICATED ABOVE REFER TO THE CROSS-SECTION OF THE
INTERNAL CONDUCTOR.
3.2
Room ventilation
The room containing the appliance should have an air supply in accordance with the standards in
force. The room where the appliance is installed must have enough air flow as required for the
regular combustion of gas and by the necessary air exchange of the same room. The air vents,
protected by grills, must be suitably dimensioned in compliance with the current regulations and
positioned so that no part of them is obstructed.
The cooker must be kept adequately ventilated in order to eliminate the heat and humidity produced
by cooking: in particular, after prolonged use, you are recommended to open a window or to
increase the speed of any fans.