Installation
95
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.75
2.9
4.0
Nozzle diameter (1/100 mm)
50
65
85
102
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
73
127
211
291
Rated flow rate G31 (g/h)
71
125
207
286
8 LPG G30/G31 – 37 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
4.0
Nozzle diameter (1/100 mm)
50
65
81
94
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
450
550
800
1600
Rated flow rate G30 (g/h)
73
131
211
291
Rated flow rate G31 (g/h)
71
129
207
286
9 LPG G30/G31 – 50 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
3.8
Nozzle diameter (1/100 mm)
43
58
74
77
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(F4)
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
73
131
211
291
Rated flow rate G31 (g/h)
71
129
207
286
10 Town gas G110 – 8 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.8
3.8
Nozzle diameter (1/100 mm)
145
185
260
340
Pre-chamber (printed on nozzle)
(/8)
(/2)
(/3)
(/13)
Reduced flow rate (W)
400
500
800
1400
WARNING:
In the case of conversion to
Town Gas G110 – 8 mbar (category
1a)
, do not use the burners provided, but request the special
G110 burners kit
from our Technical Assistance Service.