background image

2

Pumping Technology

950 rpm  

 

max. 65 dB(A)

1450 rpm  

 

0.12 kW to 1.5 kW - max. 47 dB(A), 3 kW to 7.5 kW - max. 60 dB(A), 11 kW to 45  

 

 

 

kW - max. 69 dB(A)

2900 rpm  

 

0.12 kW to 3 kW - max. 53 dB(A), 4 kW to 11 kW - max 62 dB(A), 15 kW to 45 kW -  

   max. 

78 

dB(A)

This installation guide gives basic instructions which are to be observed during installation, operation and maintenance 

of the pump. It is therefore imperative that this document be read by the responsible person/operator prior to the 
installation and always be kept available at the site. It is not only the general safety instructions under the main heading 

“Safety” that are to be observed, but also the specific information provided under the other main headings.

SAFETY

DANGER Warns of the risk of electric shock, if the precautions are not observed.

CONSTRUCTION AND APPLICATION

Smedegaard Omega pumps are of the in-line type construction with the motor mounted directly to 
the pump body. The pumps are suitable for commercial and industrial heating systems, district heating 
schemes, water treatment plants, general water transfer duties and refrigeration plants.

PUMP MEDIUM

Clean, thin, non-aggressive and non-explosive fluids (similar viscosity and specific gravity to water) 

without any solids or fibres.

TECHNICAL DATA

Electrical data    

 

see nameplate

Max. working pressure 

 

10 bar

NPSH requirements  

 

see pump performance in Omega range leaflet

Temperature 

 

  -15

o

C to +120

o

C

AIRBORNE SOUND PRESSURE LEVEL

DANGER Warns of the risk of damage to persons, property or the unit, if the precautions are not 

observed.

Antifreeze without any mineral oil (special model upon request).

Note: If any liquid other than water is being pumped, we recommend that you contact 

Smedegaard, or their representative, as the pump characteristics may change.