SMC Networks ZSE30AF-#-#-X576 Operation Manual Download Page 8

 

-7- 

 

No.PS

※※

-OMV1001

 

 

 

Do not use in a place where the product could be splashed by oil or chemicals. 

If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even 
for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires). 

Do not use in an area where surges are generated. 

If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, 
motor, etc.) close to the Pressure switch, this may cause deterioration or breakage of the internal circuit of the 
Pressure switch. Avoid sources of surge generation and crossed lines. 

Do not use a load which generates surge voltage. 

When a surge-generating load such as a relay or solenoid is driven directly, use a Pressure switch with a built-in 
surge absorbing element. 

The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes 

in the system. 

Mount the product in a place that is not exposed to vibration or impact. 

Otherwise failure or malfunction can result. 

Prevent foreign matter such as remnant of wires from entering the Pressure switch. 

Take proper measures for the remnant not to enter the Pressure switch in order to prevent failure or malfunction. 

Do not use the product in an environment that is exposed to temperature cycle. 

Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product. 

Do not expose the product to direct sunlight. 

If using in a location directly exposed to sunlight, shade the product from the sunlight. 
Otherwise failure or malfunction can result. 

Keep within the specified fluid and ambient temperatures range. 

The fluid and ambient temperatures should be 0 to 50 °C. Operation under low temperature (5 °C or less) leads to 
cause damage or operation failure due to frozen moist in the fluid or air. 
Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water. 
Avoid sudden temperature change even within specified temperature. 

Do not operate close to a heat source, or in a location exposed to radiant heat. 

Otherwise malfunction can result. 

Adjustment and Operation 

Turn the power on after connecting a load.

 

Otherwise it can cause excess current causing instantaneous breakage of the Pressure switch. 

Do not short-circuit the load. 

Although error is displayed when the Pressure switch load is short circuit, generated excess current lead to cause 
the damage of the Pressure switch. 

Do not press the setting buttons with a sharp pointed object. 

It may damage the setting buttons. 

If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first. 

There will be a drift on the display and the analogue output of approximate 

1% immediately after the power supply 

is turned on, within 10 minutes. 

Perform settings suitable for the operating conditions. 

Incorrect setting can cause operation failure. 
For details of each setting, refer to page 

19

 to 

48

 of this manual. 

Do not touch the LCD during operation. 

The display can vary due to static electricity. 

Maintenance 

Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of 

air before performing maintenance. 

There is a risk of unexpected malfunction. 

Perform regular maintenance and inspections. 

There is a risk of unexpected malfunction. 

Perform drainage regularly. 

If condensate enters the secondary side, it can cause operating failure of pneumatic equipment. 

Do not use solvents such as benzene, thinner etc. to clean the Pressure switch. 

They could damage the surface of the body and erase the markings on the body. 
Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully 
squeezed, then wipe up the stains again with a dry cloth. 

Summary of Contents for ZSE30AF-#-#-X576

Page 1: ...No PS OMV1001 PRODUCT NAME Digital Pressure Switch MODEL Series Product Number ZSE30AF X576 X580...

Page 2: ...nits selection function 24 F1 Setting of OUT1 25 F2 Setting of OUT2 28 F3 Response time 29 F4 Display resolution 32 F5 Auto preset function 33 F6 Fine adjustment of display value 35 F7 Power saving mo...

Page 3: ...quipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly Th...

Page 4: ...he failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are exclu...

Page 5: ...ul fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can res...

Page 6: ...not exceed the specified maximum allowable load Otherwise it can cause damage or shorten the lifetime of the Pressure switch Design the product to prevent reverse current when the circuit is opened o...

Page 7: ...ar never lift a Pressure switch equipped with fitting and piping by holding the lead wires Otherwise damage to the internal parts can result causing malfunction or to be off the connector Avoid repeat...

Page 8: ...damage or operation failure due to frozen moist in the fluid or air Protection against freezing is necessary Air dryer is recommended for elimination of drain and water Avoid sudden temperature change...

Page 9: ...8 No PS OMV1001 Model Indication and How to order Table1 Made to order Symbol Specification Rated pressure range X576 500 Pa X577 1 kPa X578 2 kPa X579 5 kPa X580 10 kPa...

Page 10: ...Panel mount adapter Front protective cover ZS 27 D Mounting screw M3 x 8L 2 pcs Lead wire with connector ZS 38 3L 3 cores for 1 output 2 m Lead wire with connector ZS 38 4L 4 cores for 2 outputs 2 m...

Page 11: ...lay always in red or green or display changing from green to red or red to green according to the output status button Selects the mode or increases the ON OFF set value Press this button to change to...

Page 12: ...pressure value Smooth the fluctuation of displayed value and analogue output for sharp start up or fall of the pressure When the function is valid digital filtering is reflected to the ON OFF of the...

Page 13: ...nt output Measurement mode The condition in which the pressure is detected and displayed and the switch output is operating Min setting unit Refer to digit N Normal output The switch output operation...

Page 14: ...tion Reversed output The switch output operation in which the switch is turned on when pressure equal to or less than the set value is detected In the hysteresis mode window comparator mode it indicat...

Page 15: ...of the piping port is 7 to 9 Nm The required tightening torque of the mounting bracket screws is 0 5 to 0 7 Nm Fix the bracket to the Pressure switch with the set screws M3 5L 2 pcs supplied Bracket...

Page 16: ...Panel mount adapter Front protective cover Model ZS 27 D The panel mount adapter can be rotated by 90 degrees for mounting Note when removing the switch The Pressure switch with panel mount adapter c...

Page 17: ...uperimposed and the product specification can no longer be met This can be prevented by inserting a noise filter such as a line noise filter and ferrite core between the switch mode power supply and t...

Page 18: ...ion N NPN open collector 1 output Max 28 V 80 mA Residual voltage 1 V or less P PNP open collector 1 output Max 80 mA Residual voltage 1 V or less A NPN open collector 2 outputs Max 28 V 80 mA Residua...

Page 19: ...output Max load impedance 300 at 12 V power supply voltage 600 at 24 V power supply voltage Min load impedance 50 E PNP open collector 1 output Max 80 mA Residual voltage 1 V or less Analogue voltage...

Page 20: ...gs Setting the ON and OFF points of the Pressure switch Operation When the pressure exceeds a set point the Pressure switch will be turned ON When the pressure falls below the set point by the amount...

Page 21: ...layed in turn 3 Press the or button to change the set value The button is to increase and the button is to decrease Press the button once to increase by one digit and press it continuously to keep inc...

Page 22: ...ge from P1L to P1H during window comparator mode Set P1L switch lower limit and P1H switch upper limit with the setting procedure above When reversed output is selected n1L and n1H are displayed Zero...

Page 23: ...ode Some functions are not available depending on part number All functions are displayed with F followed by the function description If a function is not available the function is displayed as Defaul...

Page 24: ...ur ON Green OFF Red F 2 Setting of OUT2 Page 28 Same setting as for F 1 OUT1 The display colour is linked to the setting of OUT1 and can not be set for OUT2 Other parameter settings Item Page Default...

Page 25: ...to set Return to function selection mode Setting of F 0 Units selection function completed Display unit and minimum setting unit Part Number Rated value kPa Pa mbar psi inHg mmHg inH2O mmH2O X576 500...

Page 26: ...ion of each setting refer to List of output modes on page 27 Operation Press the or button in function selection mode to display F 1 Press the button Move on to setting of output mode Press the button...

Page 27: ...of F 1 operation of OUT1 completed 1 The selected parameter becomes effective after pressing the button 2 After setting it is possible to move to measurement mode by pressing the button for 2 seconds...

Page 28: ...output is changed is outside the set pressure range due to switching between normal and reversed output the hysteresis will automatically be compensated The above figure shows the operation of OUT1 Fo...

Page 29: ...and can not be set for OUT2 Operation Press the or button in function selection mode to display F 2 Press the button Moves on to setting of output mode Set F 2 based on F 1 setting of OUT1 page 25 to...

Page 30: ...tion of pressure display and analogue output can be reduced by increasing the set value of the digital filter The chattering of the switch output can also be reduced Effective when the pressure fluctu...

Page 31: ...n to set Fine adjustment mode Press the button to set Press the button to set Press the button to set 1 Digital filter setting FiL Press the or button to select the desired output mode Rough adjustmen...

Page 32: ...ction selection mode Setting of F 3 Response time completed Measurement mode can be returned from any setting item by pressing the button for 2 seconds or longer 2 Delay time setting dt Press the or b...

Page 33: ...n Press the button to set Return to function selection mode Setting of F 4 Display resolution completed Not selectable depending on the selected display units Setting of display resolution may not be...

Page 34: ...on in function selection mode to display F 5 Press the button Move on to setting of auto preset Press the button to set Return to function selection mode Setting of F 5 Auto preset function completed...

Page 35: ...eset OUT2 Press the button to set P_1 and H_1 n_1 and H_1 for reversed mode and display AP2 If OUT2 does not need to be set press the and buttons simultaneously for 1 second or longer to return to mea...

Page 36: ...display F 6 Press the button Move on to setting of fine adjustment of display value Press the button to set Press the button to set Return to function selection mode Setting of F 6 Fine adjustment of...

Page 37: ...unction selection mode Setting of F 7 Power saving mode completed In power saving mode any key operation will return the normal display If there is no key operation for 30 seconds the display will ret...

Page 38: ...n to setting of security code Press the button to set Return to function selection mode Setting of F 8 Security code completed If the security code is used it becomes necessary to enter the security c...

Page 39: ...5 X578 2 kPa 0 01 10 0 1 0 001 0 003 0 1 0 04 1 X579 5 kPa 0 03 0 3 0 004 0 01 0 2 0 1 3 X580 10 kPa 0 05 0 5 0 01 0 01 0 4 0 2 5 Low cut function not available No units for display Operation Press th...

Page 40: ...tion mode on used selected Setting of each function 1 After the change to oFF unused press the button to set Return to function selection mode Press the button for 2 seconds or longer F90 Setting of a...

Page 41: ...the product with output specification of NPN2 and PNP2 8 Select reversed output OUT2 9 Setting of pressure OUT2 10 Setting of hysteresis OUT2 11 Response time All models 12 Display resolution All mod...

Page 42: ...with the power supply turned off Connect the FUNC terminals of the master Pressure switch and the slave Pressure switches and then turn on the power supply The master Pressure switch is the switch fro...

Page 43: ...is not completed it is detected as a copy function sending receiving error Press the and buttons simultaneously for 1 second or longer to return to measurement mode Then check the wiring and specific...

Page 44: ...set Return to function selection mode If F forcibly output is selected Press the button to set If OUT2 output is not provided press the button to set after returning to A normal output Return to func...

Page 45: ...to A normal output Return to function selection mode Press the button for 2 seconds or longer Setting of F98 Check of output completed Measurement mode If the button is pressed for 2 seconds or longer...

Page 46: ...the button Move on to reset to the default setting oFF unused selected Press the button to set Return to function selection mode The setting is reset to the default setting and the mode returns to the...

Page 47: ...o clear The displayed value can be adjusted to zero when the measured pressure is within 3 5 F S of the pressure at the time of shipment from the factory A tolerance range of 1 F S may apply due to in...

Page 48: ...ton to select keys unlock UnL 3 When the button is pressed input of the security code will be requested For how to enter the security code refer to How to enter the security code on page 48 4 If the s...

Page 49: ...ew security code will be displayed 3 After checking the security code is as required press the button for 1 second or longer The display will return to measurement mode At this time if the or button i...

Page 50: ...r cut or de energizing The output condition is also basically recovered to that before a power cut or de energizing but may change depending on the operating environment Therefore check the safety of...

Page 51: ...he display will return to measurement mode Press the and buttons simultaneously for 5 seconds or longer The display will change to 0000 and the security code change mode will return at this time if an...

Page 52: ...te correctly Refer to Fault No 1 The switch output is ON The Indicator LED is ON The indicator LED operates incorrectly The switch output is OFF The switch output is chattering The Indicator LED is OF...

Page 53: ...Fault No 8 The display is not normal Refer to Fault No 9 Refer to Fault No 9 Refer to Fault No 11 Refer to Fault No 14 Refer to Fault No 13 Refer to Fault No 15 Refer to Fault No 16 The display break...

Page 54: ...ther way around Review the selected model output type Broken lead wire Check if there is bending stress applied to any parts of the lead wire bending radius and tensile force applied Correct the wirin...

Page 55: ...fied 3 Use a relay with a surge voltage suppressor or take measures to prevent noise 4 Separate the wiring route from any high voltage cable or power cable Incorrect operation of the internal data of...

Page 56: ...to 24 VDC 10 Supply the correct voltage of 12 to 24 VDC 10 Power saving mode Check if the power saving mode is selected Reset the function settings Incorrect wiring Check the power supply wiring Check...

Page 57: ...tion of model without units selection function Check if there is an M at the end of the part number printed on the product M in the part number means that the units cannot be changed The unit change f...

Page 58: ...units specification are identical Too many pressure switches connected Check the number of connected slave Pressure switches The number of connected products for which copying is possible is up to 10...

Page 59: ...rement mode The zero clear range can vary 1 F S with individual product differences Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure condition Pressur...

Page 60: ...oad current Delay time 4 ms or less with anti chatter function 20 ms 100 ms 500 ms 1000 ms 2000 ms 10 s 30 s or 60 s selected Short circuit protection Provided Repeatability 1 F S 1 digit Hys teresis...

Page 61: ...perature characteristics 3 F S 25 C reference Lead wire Oil resistant vinyl cabtyre cable 3 cores 3 5 2 m 4 cores Sectional area of conductor 0 15 mm2 AWG26 Outside diameter of insulator 1 0 mm Fig Re...

Page 62: ...22 107 1 X578 2 kPa 2 10 1998 to 2100 21 0 0 305 0 620 15 8 8 43 214 X579 5 kPa 5 25 52 5 0 761 1 55 39 4 21 1 535 X580 10 kPa 10 50 105 0 1 52 31 0 78 8 42 2 1071 No units for display Analogue output...

Page 63: ...62 No PS OMV1001 Dimensions Body dimensions...

Page 64: ...63 No PS OMV1001 Mounting brackets Bracket A Bracket B...

Page 65: ...64 No PS OMV1001 Bracket C...

Page 66: ...65 No PS OMV1001 Panel mount adapter Panel mount adapter Front protective cover...

Page 67: ...66 No PS OMV1001 Panel cut out dimensions Single Pressure switch Two or more in a row n The number of the Pressure switch Horizontal Vertical...

Page 68: ...hiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manu...

Reviews: