background image

Z/ISE3-TFK26GB-A

Error Display

Error Nature

Troubleshooting Method

The set data has been 
changed by some 
means.

Press the RESET button 
and set all data again.

Load of OUT1 has short-
circuited and overcurrent 
has occurred.

Turn off the power 
supply and replace the 
load connected to the 
OUT1 (black wire).

Load of OUT2 has short-
circuited and overcurrent 
has occurred.

Turn off the power 
supply and replace the 
load connected to the 
OUT2 (white wire).

Pressure exceeding 0.5 
MPa has been applied 
(In case of positive 
pressure, pressure 
exceeding the rated 
pressure has been 
applied.)

Lower the pressure to 
0.5 MPa or less. (In case 
of positive pressure, 
lower the pressure to the 
rated pressure or less.)

Compared with the 
ambient pressure,   0.07 
MPa (in case of 1 MPa 
use) or   7 kPa or more 
(in case of vacuum use 
or 100 kPa use) has 
been applied during 0 
clear.

After adjusting the 
pressure to the ambient 
pressure, perform 
RESET operation.

When an error occurs, take actions as follows.

Output Specification

-21

Switch Output
NPN open collector output
2 outputs
Max. 30 V, 80 mA

-22

Switch Output
NPN open collector output
2 outputs
Max. 30 V, 80 mA
Analogue output 1 to 5V
(±5%F.S.)
Output impedance: Approx. 1 k

-23

Switch Output
NPN open collector output
1 output
Max. 30 V, 80 mA
Failure predictive output
NPN open collector output
1 output

-24

Switch Output
NPN open collector output
1 output
Max. 30 V, 80 mA
Failure predictive output
NPN open collector output
1 output
Analogue Output (±5 %F.S)
1 to 5V (±5 %F.S.)
Output impedance: Approx. 1 k

LED Green

LED Red

M

a

in

c

ir

c

u

it

+

-

DC
12 to 24V

Load

Load

Tr1 D1

Tr2

D2

Brown [+]

Black [1]

White [2]

Blue [-]

OUT1

OUT2

LED Green

LED Red

M

a

in

c

ir

c

u

it

+

-

DC
12 to 24V

Load

Load

Tr1 D1

Tr2

D2

Brown

Black

White

Blue

Grey

Analogue output

OUT1

OUT2

LED Green

LED Red

M

a

in

c

ir

c

u

it

+

-

DC
12 to 24V

Load

Load

Tr1 D1

Tr2

D2

OUT1

Failure predictive output

Brown [+]

Black [1]

White [2]

Blue [-]

LED Green

LED Red

M

a

in

c

ir

c

u

it

+

-

DC
12 to 24V

Load

Load

Tr1 D1

Tr2

D2

Brown

Black

White

Blue

Gray

Analogue output

OUT1

Failure predictive output

Connector Connecting

• When connecting a connector, insert the connector straight by tightly

holding its lever and body and lock it, making sure the lever hook is
securely locked into the groove of the housing.

Connector Disconnecting

• When disconnecting the connector, pull it straight away from the hous-

ing by pressing the lever and removing the lever hook from the groove.

Connector

Lever

Pins

Slot

9. Internal Circuit and Wiring

Replacement of Filter Elements

If filter element clogging causes deterioration of the absorption force or
slows the response time, stop operation and replace the filter element.

Filter Element product number : ZX1-FE

Confirm that the filter gasket is seated in the groove before reassembling
the parts.

Filter Case

The case is made of polycarbonate. Therefore, do not use it in an
environment that is exposed to chemicals such as thinner, carbon
tetrachloride, chloroform, acetic ester, aniline, cyclohexane,
trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting
oil (alkalinic).

Filter case

Filter element (ZX1-FE)

Filter gasket

Gasket groove

10. Maintenance

Connector Wiring

Crimping of Lead Wire and Socket

Strip 3.2 to 3.7 mm from the tip of the lead wire and fit a crimp using
the recommended crimping tool. Then insert the core wires carefully
into a socket.
Ensure that the cover of the lead wire does not enter the wire crimp-
ing area (Crimping tool: model no. DXT170-75-1).

Attachment of Socket with Lead Wire

Insert a socket into the square hole in the connector (+, 1, 2, – indi-
cation provided).
Holding by the lead wire, push it all the way in until the hook on the
socket catches and locks in the seat of the connector. (When the lead
wire is pushed in, the hook opens and locks it automatically.) Then
pull the lead wire gently to confirm that it is locked.

Removal of Socket with Lead Wire

To remove a socket from the connector, pull the lead wire out while
pressing in the socket’s hook using a bar with a thin end (approxi-
mately 1 mm). If the socket is to be re-used, open the hook outward.

Lead wire

0.2 to 0.33mm

2

Max. sheathed dia.

ø

1.7mm

Socket
Model DXT170-71-1

Pin assignment

Hook

Housing

Connector

Lever

Pins

Slot

11. Error Indication

AUSTRIA

(43) 2262 62280

NETHERLANDS

(31) 20 531 8888

BELGIUM

(32) 3 355 1464

NORWAY

(47) 67 12 90 20

CZECH REP.

(420) 541 424 611

POLAND

(48) 22 211 9600

DENMARK

(45) 7025 2900

PORTUGAL

(351) 21 471 1880

FINLAND

(358) 207 513513

SLOVAKIA

(421) 2 444 56725

FRANCE

(33) 1 6476 1000

SLOVENIA

(386) 73 885 412

GERMANY

(49) 6103 4020

SPAIN

(34) 945 184 100

GREECE

(30) 210 271 7265

SWEDEN

(46) 8 603 1200

HUNGARY

(36) 23 511 390

SWITZERLAND

(41) 52 396 3131

IRELAND

(353) 1 403 9000

UNITED KINGDOM

(44) 1908 563888

ITALY

(39) 02 92711

URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)

Specifications are subject to change without prior notice from the manufacturer.
The descriptions of products in this document may be used by other companies.
© SMC Corporation All Rights Reserved.

Contact

Reviews: