background image

VFS2000-TF2Z523EN-A 

 

Page 1 of 3 

 

 

Instruction Manual    

5 Port Pilot Operated Solenoid Valve 

VFS1000/2000/3000/4000/5000/6000 Series 
and VF2-4, Metal Seal  

 

 

The intended use of this valve is to control the movement of an actuator.

 

1 Safety Instructions 

These  safety  instructions  are  intended  to  prevent  hazardous  situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines.        
(Part 1: General requirements) 
ISO  10218-1:  Robots  and  robotic  devices  -  Safety  requirements  for 
industrial robots - Part 1: Robots. 

  Refer  to  product  catalogue,  Operation  Manual  and  Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 
not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 
not avoided, will result in death or serious injury. 

 Warning 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

  If  this  equipment  is  used  in  a  manner  not  specified  by  the 

manufacturer,  the  protection  provided  by  the  equipment  may  be 
impaired. 

 Caution 

  The  product  is  provided  for  use  in  manufacturing  industries  only. Do 

not use in residential premises. 

2 Specifications 

2.1  Valve specifications 

Type 

Body ported 

Base mounted 

2 position 

3 position 

Fluid 

Air 

Operating 
pressure 
range 
[MPa]  

For 
internal 
pilot 

VFS3000 

0.1 to 1 

VFS5000/6000 

0.1 to 1 

VFS2000 

0.1 to 1 

0.15 to 1 

VFS4000 

0.1 to 1 

0.15 to 1 

VFS1000 

2 position  0.1 to 1 

3 position  0.15 to 1 

For external pilot 

0 to 1 

External pilot pressure 
range [MPa] 

VFS3000/5000/6000 

0.1 to 1 

VFS2000/4000 

0.1 to 1 

0.15 to 1 

Proof pressure [MPa] 

1.5  

Ambient and fluid temperature [°C] 

Note 1)

 

-10 to 60 

Flow characteristics 

Refer to catalogue 

Response time 

Refer to catalogue 

Duty cycle 

Contact SMC 

2 Specification - continued 

Type 

Body ported

 

Base mounted 

Min. operating frequency 

1 cycle / 30 days 

 Max. operating frequency [cycles/min] 

Refer to catalogue 

Manual override 

Non-locking push type 

(Flush/Extended), Locking type (Tool 

required/Lever) 

Lubrication

 

Not required 

Impact/Vibration resistance [m/s

2

Note 2) 

150 / 50 

Enclosure 
(Equivalent 
based on 
JIS C 
0920) 

VFS1000 

IP50 

VFS2000 

With 
light/surge 
voltage 
suppressor 

G, E, F: IP50 

T, D: IP54 

VFS5000 

VFS3000 

IP50 

VFS4000/6000 

IP50 

VFS2000 

Without 
light/surge 
voltage 
suppressor 

IP50 

G, E: IP50 

F, T, D: IP54 

VFS3000 

E: IP50 
F: IP52 
D: IP54 

VFS4000/5000/6000 

Mounting orientation 

Note 3)

  

Unrestricted 

Weight 

Refer to catalogue 

Table 1. 

Note 1)  Use dry air at low temperatures. 
Note 2)  Impact  resistance: No malfunction  occurred  when it is tested with  a  drop 

tester in the  axial direction and  at the  right angles to the main  valve and 
armature  in  both  energized  and  deenergized  states  every  once  for  each 
condition. (Values quoted are for a new valve) 
Vibration resistance: No malfunction occurred in a one-sweep test between 
45 and 2000 Hz. Test was performed at both energized and de-energized 
states in the axial direction and at the right angles to the main valve and 
armature. (Values quoted are for a new valve) 

Note 3)  In  the  case  of  double  solenoid,  mount  the  valve  so  that  the  spool  is 

horizontal. 

2.2  Solenoid specifications 

Pilot valve part number 

SF4-####-## 

Coil rated 
voltage  

AC (50/60 Hz) [VAC] 

100, 110 to 120, 200, 220, 240 

DC [VDC] 

12, 24, 100 

 

Electrical entry 

Base mounted  

Grommet, Grommet terminal, 

Conduit terminal, Conduit terminal 

(Plug-in), DIN terminal 

Body ported 

Grommet, Grommet terminal, 

Conduit terminal, DIN terminal 

Coil insulation class  
(Based on JIS C 4003) 

Class B or equivalent 

Allowable voltage fluctuation 

Note) 

–15 to +10% of rated voltage 

Apparent power [VA] 

Inrush 

5.6 (50 Hz), 5.0 (60 Hz) 

Holding 

3.4 (2.1 W) / 50 Hz,  

2.3 (1.5 W) / 60 Hz 

Power consumption [W] 

1.8 (2.04 with light/surge voltage 

suppressor) 

Surge voltage suppressor  

Varistor, Diode (DC Grommet) 

Indicator light 

AC, 100 VDC 

Neon light 

12, 24 VDC 

LED 

Table 2. 

 Note) Valve state is not defined if electrical input is outside of specified operating 

ranges. 

2.3  Manifold specifications  

2.3.1 Body ported VFS1000/2000/3000 

2.3.1.1 Manifold specifications  

Body type 

Applicable manifold base (Pilot EXH) 

VFS(1/2)#20 

Bar manifold (Individual EXH) 

VFS3#20 

Stacking manifold (Individual EXH) 

VFS(1/2)#30 

Bar manifold (Common EXH base side) 

VFS3#30 

Stacking manifold (Common EXH base side) 

Table 3. 

Note) VFS(1/2)#30 is manifold only. Cannot be used as a single unit. 

2.3.1.2 Port specification 

Series 

Passage 

Port specification: Rc  

Base 

Valve 

Base 

1(P) 

5(R1), 3(R2) 

1(P) 

4(A), 2(B)  5(R1),3(R2) 

VFS1000 

Common 

Common 

Side 1/8 

Top 1/8 

Side 1/8 

VFS2000 

Side 3/8 

Top 1/8, ¼ 

Side 3/8 

VFS3000 

Top ¼, 3/8 

Table 4. 

2 Specification - continued 

2.3.2 Base mounted VFS2000/3000/4000/5000 

2.3.2.1 Manifold specifications 

Base model 

Plug-in type 

VV5FS(2/3/4/5)-01 

Non plug-in type 

VV5FS(2/3/4/5)-10 

Stations

 Note 1)

 

VFS2000 

2 to 16 

VFS3000 

1 to 16  

VFS4000 

2 to 10 

VFS5000 

External pilot 

Yes 

Note 2) 

Applicable valve 
model 

Note 2) 

VFS2000 

VFS2#00-#F 

VFS2#10-#(G/E/T/D) 

VFS3000 

VFS3#0#(R)-#F(Z)  VFS3#1#(R)-#(D/E)(Z) 

VFS4000 

VFS4#0#(R)-#F(Z) 

VFS4#1#(R)-#(D/E)(Z) 

VFS5000 

VFS5#0#(R)-#F(Z) 

VFS5#1#(R)-#(D/E)(Z) 

Table 5. 

Note 1) With multi-connector, or with D-sub connector: 8 stations max. 
Note 2) It is possible to mount the standard valve and external pilot type together.  

2.3.2.2 Port specifications 

Series 

Passage 

Port specification: Rc  

P, EA, EB 

Side ported  Bottom ported 

EA, EB 

A, B 

A, B 

VFS2000 

Common / Individual 

1/4

 

1/8, 1/4 

1/8 

VFS3000 

Common 

1/2 

Note 1)

 

1/4, 3/8 

1/4 

VFS4000 

1/2 

3/8, 1/2 

3/8 

VFS5000 

3/4 

1/2, 3/4 

1/2 

Table 6. 

Note 1) For VFS3000 appropriate silencer for EA, EB port: AN40-04 

2.4  Pneumatic symbol  

Refer to catalogue for pneumatic symbol. 

2.5  Indicator light 

Indicator lights are labelled as A or B on the valve. Refer to catalogue for 
indicator light locations. 

2.6  Special products 

 Warning 

Special  products  (-X)  might  have  specifications  different  from  those 
shown in this section. Contact SMC for specific drawings. 

3 Installation 

3.1  Installation 

 Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

3.2  Environment 

 Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result in 

temperatures in excess of the product’s specifications. 

  Products  compliant  with  IP50,  IP52  and IP54  have limited  protection 

against dust. 

  Products  compliant  with  IP52  are  protected  against  water  drips  and 

products  compliant  with  IP54  are  protected  against  water  splashes. 
However, these products cannot be used in water. 

  Products  compliant  with  IP50,  IP52  and  IP54  enclosures  satisfy  the 

specifications by mounting each product properly. Be sure to read the 
Specific Product Precautions for each product. 

  Do  not  use  in  high  humidity  environment  where  condensation  can 

occur. 

  Contact SMC for altitude limitations. 

3.3  Piping 

 Caution 

  Before connecting piping make sure to clean up chips, cutting oil, dust 

etc. 

  When  installing  piping  or  fittings,  ensure  sealant  material  does  not 

enter inside the port. When using seal tape, leave  1 thread

 

exposed 

on the end of the pipe/fitting.  

  Tighten fittings to the specified tightening torque. 

 

Installation - continued 

Connection thread size 

Tightening torque [N·m] 

M5 

1 to 1.5 

1/8 

3 to 5 

1/4 

8 to 12 

3/8 

15 to 20 

1/2 

20 to 25 

3/4 

28 to 30 

36 to 38 

Table 7. 

  Refer to catalogue for port identification and sizes. 

3.4  Lubrication 

 Caution 

  SMC products have been lubricated for life at manufacture, and do not 

require lubrication in service. 

  If a lubricant is used in the system, refer to catalogue for details. 

3.5  Air Supply  

 Warning 

  Use  clean  air.  If  the  compressed  air  supply  includes  chemicals, 

synthetic materials (including organic solvents), salinity, corrosive gas 
etc., it can lead to damage or malfunction. 

 Caution 

  Install  an  air  filter  upstream  of  the  valve.  Select  an  air  filter  with  a 

filtration size of 5 μm or smaller. 

3.6  Manual override 

 Warning 

  Regardless of an electric signal for the valve, the manual override is 

used  for  switching  the  main  valve.  Since  connected  equipment  will 
operate when the manual override is activated, confirm that conditions 
are safe prior to activation. 

  Locked manual overrides might prevent the valve responding to being 

electrically  de-energised  or  cause  unexpected  movement  in  the 
equipment. 

  Refer to the catalogue for manual override location. 

  To operate the non-locking manual override, push the manual override 

until it stops.  

  To  operate  the  locking  manual  override,  use  a  tool  (not  required  for 

lever type) to turn the manual override 90° in the "1" direction, the valve 
will  turn  on  and  lock.  To  cancel  the  ON  state,  turn  it  90°  in  the  "0" 
direction and check that it is in the OFF state. 

 

Figure 1. Locking manual override (Tool required type shown) 

3.7  Mounting 

 Caution 

  Ensure gaskets are in good condition, not deformed and are dust and 

debris free. 

  When mounting valves to a manifold or sub-plate ensure gaskets are 

present,  aligned  and  securely  in  place  and  tighten  to  the  torque 
indicated in the table below. 

  Refer specific product precautions for how to exchange solenoid valve. 

Series 

Mounting screw size 

Tightening torque [N·m] 

VFS1000 

M4 

1.4 to 2.5 

VFS2000 

M3 

0.8 to 1.2 

VFS3000 

M4 

1.4 to 2.5 

VFS4000 

M4 

1.4 to 2.5 

VFS5000 

M5 

2.8 to 5 

VFS6000 

M8 

11.0 to 15.0 

Table 8. 

  Attach/remove  solenoid  valve  vertically,  parallel  to  sub-plate, 

otherwise  it  may  cause  damage  to  the  solenoid  valve  and 
pin/receptacle assembly. Never remove a valve at an angle. 

ORIGINAL INSTRUCTIONS 

 

 

 

  OFF State 

  ON State 

Reviews: