6 Maintenance - continued 

  Do  not  disassemble  the  product,  unless  required  by  installation  or 

maintenance instructions. 

6.2  Mounting 

 Caution 

Refer to 3.7 for details. 

6.3  Maintainable parts 

 Caution 

  Refer to specific product precautions in catalogue for how to order and 

exchange pilot valve. 

  To mount pilot valve to valve body, tighten the M3 mounting screws to 

a torque of 0.45 to 0.6 N∙m.  

  Refer  to  catalogue  for  how  to  order  light/surge  voltage  suppressor 

substrate, sub-plate assemblies, manifolds, manifold accessory parts 
and mounting bolts and gasket. 

 Warning 

  Body ported VFS1000/2000/3000 and base mounted VFS2000: When 

changing rated voltage and electrical entry etc., pilot valve assembly 
can be changed. However, in the case of plug-in type with light/surge 
voltage suppressor, rated voltage cannot be changed by changing pilot 
valve assembly.  

  Base  mounted  VFS3000/4000/5000/6000:  When  changing  rated 

voltage and electrical entry etc., pilot valve assembly can be changed. 
However,  when  changing  the  rated  voltage  of  a  valve  with  indictor 
light/surge voltage suppressor, it is required to change both the pilot 
valve  and  indictor  light/surge  voltage  suppressor  substrate,  refer  to 
catalogue  for  how  to  access/remove  light/surge  voltage  suppressor 
substrate. 

7 Limitations of Use 

 Warning 

The system designer should determine the effect of the possible failure 
modes of the product on the system. 

7.1  Limited warranty and disclaimer/compliance requirements 

Refer to Handling Precautions for SMC Products. 

 Warning 

7.2  Effect of energy loss on valve switching  

  The  use  of  2-position  single  valves  with  combined  air  and  spring 

returned spools has to be carefully considered. 

  The return of the valve spool into the de-energized position depends 

on  the  pilot  pressure.  If  the  pilot  pressure  drops  below  the  specified 
operating pressure the position of the spool cannot be defined. 

  The design of the system must take into account such behaviour. 

  Additional measures might be necessary. For example, the installation 

of an additional air tank to maintain the pilot pressure.  

 

 

Spool position 

Single 

solenoid 

Double solenoid 

3 Position 

Air supply 

present,  

electrical 

supply cut 

Spool at the 
end position 

Spool 

returns to 

the OFF 

position by 

air and 

spring force. 

Spool holds 

position 

Spool returns to 

the OFF position 

by spring force. 

During spool 

movement 

(Spool at 

intermediate 

position) 

Spool stops 

moving after 

electricity cut 

(Position cannot 

be defined) 

Electrical 

supply 

present,  

air supply cut 

Spool at the 
end position 

Spool 

returns to 

the OFF 

position by 

spring force. 

Spool holds 

position 

During spool 

movement 

(Spool at 

intermediate 

position) 

Spool stops 

moving after air 

pressure cut 

(Position cannot 

be defined) 

Table 10. 

 

7.3  Intermediate stopping 

Refer to Handling Precautions for 3/4/5 port Solenoid Valves. 

7.4  Holding of pressure 

Since  valves  are  subject  to  air  leakage,  they  cannot  be  used  for 
applications such as holding pressure (including vacuum) in a system. 

7 Limitations of Use - continued 

7.5  Cannot be used as an emergency shut-off valve 

This  product  is  not  designed  for  safety  applications  such  as  an 
emergency shut-off valve. If the valves are used in this type of system, 
other reliable safety assurance measures should be adopted. 

 Caution 

7.6  Safety relays or PLC 

If a safe output from a safety relay or PLC is used to operate this valve, 
ensure that any output test pulse duration is shorter than 1 ms to avoid 
the valve solenoid responding. 

7.7  Leakage voltage  

Ensure that any leakage voltage caused by the leakage current when the 
switching element is OFF causes 

≤ 3% (for DC coils) or ≤ 20% (for AC 

coils) of the rated voltage across the valve. 

7.8  Low temperature operation 

Unless otherwise indicated in the specifications for each valve, operation 
is possible to -

10˚C, but appropriate measures should be taken to avoid 

solidification or freezing of drainage and moisture, etc. 

7.9  Momentary energization 

If  a  double  solenoid  valve  is  operated  with  momentary  energization,  it 
should be energized for at least 0.1 second. However, depending on the 
secondary  load  conditions,  it  should  be  energized  until  the  cylinder 
reaches the stroke end position, as there is a possibility of malfunction 
otherwise. 

8 Product Disposal 

This  product  shall  not  be  disposed  of  as  municipal  waste.  Check  your 
local regulations and guidelines to dispose this product correctly, in order 
to reduce the impact on human health and the environment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 Contacts 

Refer  to  www.smcworld.com  or  www.smc.eu  for  your  local 
distributor/importer. 

 

 