The maximum operating pressure differential differs depending 
on the flow direction of the fluid. If the pressure differential at 
each port exceeds the values in the table below, valve leakage 
may occur.

Model

VDW30

VDW40

1.0

3.0

4.5

6.0

Orifice diameter

(mm ø)

Max. operating pressure differential

(MPa)

Pressure port 1

0.6

0.1

0.1 (With power-saving circuit)

0.05 (Without power-saving circuit)

0.05 (With power-saving circuit)

0.02 (Without power-saving circuit)

2 Port Valve

Fluid Flow Direction

Caution

For information on handling One-touch fittings and 
appropriate tubing, see Series KQ2 One-touch fittings 
in Best Pneumatics No. 6. It can be downloaded from 
the SMC Web site: http://www.smcworld.com/

One-touch Fittings

Caution

OUT

(2)

(1)

IN

SOL.

Power-saving

circuit

Red (+)

Black (–)

DC circuit

Standard coil

Coil with power-saving circuit

1 (+, –)

2 (–, +)

SOL.

Electrical Connections

Caution

1. Solenoid valves with power-saving circuits (coil 

part number “-5GE”) have polarity, so follow the 
wiring diagram below when making connections. 
Standard coils have no polarity.

The solenoid valve will not switch properly if the polarity is re-
versed.

2.  Apply the correct voltage. 

Incorrect voltage could cause shorting of the power-saving cir-
cuit, coil burnout, or valve malfunction.

3. Do not apply a tension load of 30 N or more to the 

solenoid valve lead wires.

4.  Apply voltage which is within 

±

10% of the rated vol-

tage.

Also, do not use excessive power supply voltage or superim-
pose electrical noise such as ripple voltage on the power sup-
ply voltage as these could harm the valve.

5. When connecting an induction load such as a cir-

cuit protector to the solenoid valve connection, 
take measures to ensure that the current to the sol-
enoid valve is not reduced too much.

Maintenance

Warning

1.  Do not disassemble solenoid valves.

Disassembling a solenoid valve will void its warranty.

2.  Low frequency operation

Switch valves at least once every 30 days to prevent 
malfunction. Also, in order to use it under the optimum state, 
conduct a regular inspection once a half year.

Caution

1. Store indoors in a location away from direct sun-

light and where the following conditions are main-
tained.

• Temperature: –10 to 50

°

C

• Relative humidity: 20% to 85%RH (No condensation)
• Liquid rings may not be used.

2. Storage

When not using for a long time (more than approx. one 
month) after use with liquid, thoroughly remove all moisture to 
prevent rust and deterioration of rubber materials, etc.

Series 

VDW30/40 

Specific Product Precautions 2

Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling
Precautions for SMC Products” (M-E03-3) for Fluids Control 2 Port Valves Precautions, 
and Series VDW in Best Pneumatics No. 7 for Specific Product Precautions.

7

VDW30-Info.qxd  10.5.31 10:51 AM  Page 7

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Summary of Contents for VDW30-XF Series

Page 1: ...NEDO In principle supply of the product for household fuel cell system applications with a capacity of 3 kW or less commences in April 2010 Application Examples Information Akihabara UDX 15F 4 14 1 So...

Page 2: ...alve type 3 4 30 40 Series Nil E None With power saving circuit Power saving circuit OUT 2 1 IN G Grommet Coil type How to Order Valves Single Unit Compact Lightweight 2 Port Solenoid Valve Series VDW...

Page 3: ...s are inserted Soft nylon tubing cannot be used with water P10 C8 C10 Valve construction Valve type Fluid Withstand pressure Ambient temperature Fluid temperature Ambient humidity Environment Valve le...

Page 4: ...ainless steel Iron NBR FKM EPDM Iron POM Stainless steel NBR FKM EPDM Do not disassemble Caution Dimensions VDW30 G P7 P7 Quick Fastener Male Quick Fastener Dimensions VDW40 G P10 P10 Quick Fastener P...

Page 5: ...C8 C10 Dimentions Series VDW40 A 3 4 C8 C10 For information on handling One touch fittings and appropriate tubing see Series KQ2 One touch fittings in Best Pneumatics No 6 It can be downloaded from t...

Page 6: ...vent uncontrolled tube movement install protective covers or fasten tubes securely in place 2 or less of rated voltage DC coil 2 Low temperature operation 1 The valves can be used up to an ambient tem...

Page 7: ...rated vol tage Also do not use excessive power supply voltage or superim pose electrical noise such as ripple voltage on the power sup ply voltage as these could harm the valve 5 When connecting an i...

Page 8: ...uring industries The product herein described is basically provided for peaceful use in manufacturing industries If considering using the product in other industries consult SMC beforehand and exchang...

Reviews: