Pitch indication (Series KQB2): All installation lengths with the same pitch
Pitch indication (Series KR-W2): All installation lengths with the same pitch
Installation on the KR-W2 series
Step 1
Step 2
Pitch length for installation on a one-touch fitting is indicated on the outer layer of the TRTU tubing.
(There are two types of applicable fittings, so two types of pitch length for installation are available.)
Cut the tube according to this indication (Step 1) and strip off the outer layer (Step 2) using a special tool.
Strip off the aluminum laminated film to prevent the inner tube from being damaged (Step 3) and install it on the one-touch fitting.
Refer to the Operation Manual for details of installation on the one-touch fitting.
The Operation Manual can be downloaded from the SMC URL below.
http://www.smcworld.com/
Strip off the outer layer.
Step 3
Strip off the aluminum laminated film to prevent
the inner tube from being damaged.
Metal one-touch fittings
Series
KQB2
Flame resistant
(equivalent to UL-94 standard V-0)
FR one-touch fittings
Series
KR-W2
Identification of the pitch length
for installation
“ ”: Series
KQB2
“ ”: Series
KR-W2
Outer layer, aluminum laminated film
and inner tube are cut at the “ ” mark.
Use a special tool for stripping
off the outer layer.
Part no.: YS-100
∗
Refer to the Operation Manual
for details of how to use the
special
tool.
Special tool
Series
TRTU
Flame Resistant (Equivalent to UL-94 Standard V-0)
FR Three-layer Polyurethane Tubing
Tube
2
Installation on One-touch Fittings
TRTU-A.qxd 10.7.22 5:21 PM Page 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com