background image

Pitch indication (Series KQB2): All installation lengths with the same pitch

Pitch indication (Series KR-W2): All installation lengths with the same pitch

Installation on the KR-W2 series 

Step 1

Step 2

Pitch length for installation on a one-touch fitting is indicated on the outer layer of the TRTU tubing.
(There are two types of applicable fittings, so two types of pitch length for installation are available.)
Cut the tube according to this indication (Step 1) and strip off the outer layer (Step 2) using a special tool.
Strip off the aluminum laminated film to prevent the inner tube from being damaged (Step 3) and install it on the one-touch fitting.  
Refer to the Operation Manual for details of installation on the one-touch fitting. 

The Operation Manual can be downloaded from the SMC URL below.
http://www.smcworld.com/

Strip off the outer layer.

Step 3

Strip off the aluminum laminated film to prevent 
the inner tube from being damaged.  

Metal one-touch fittings

Series 

KQB2

Flame resistant

(equivalent to UL-94 standard V-0)

FR one-touch fittings

Series 

KR-W2

Identification of the pitch length 
for installation 
“   ”: Series 

KQB2

“   ”: Series 

KR-W2

Outer layer, aluminum laminated film 
and inner tube are cut at the “  ” mark. 

Use a special tool for stripping 
off the outer layer. 

Part no.: YS-100

 Refer to the Operation Manual 

  for details of how to use the 
 special 

tool.

Special tool

Series 

TRTU

Flame Resistant (Equivalent to UL-94 Standard V-0)

FR Three-layer Polyurethane Tubing

Tube

2

Installation on One-touch Fittings

TRTU-A.qxd  10.7.22 5:21 PM  Page 3