Disable Zones 

The SMA system can bypass a zone, so the zone is not 
monitored when the system is armed. This is useful when a 
sensor is being repaired. You can only change the Bypass 
state of a zone when the system is disarmed.  

The system continues to log the activity of bypassed zones in 

the Event History (see “View Zone Event History,” above). 

To bypass a zone: 

A.

 

With the system disarmed, touch the 

Security

 icon on 

the Home screen. 

B.

 

When the Dashboard screen appears, touch the 

Bypass

 

button for the zone to be bypassed. The Bypass button 
of the zone changes to show it is bypassed. 

When the system is disarmed, the Security Status header 
notes that some of the zones have been bypassed. 

8   

Deleting a Sensor 

Deleting a sensor from the premises removes it from being 
monitored by the customer’s SMA system. This is not the 
same as disabling (bypassing) a sensor. You should delete a 
sensor only: 

 

If the sensor is being de-installed from the SMA premises  

 

To reset the sensor to factory default settings by 
deleting the sensor and re-adding it immediately. 

To delete a sensor from the SMA system:  

A.

 

Perform steps A through D in step 2, “Add the SMCDW01-
Z to the SMA.” 

B.

 

When the Technician Settings menu appears, select 

Sensors & Zones > Delete a Sensor/Zone

.

 

C.

 

When the Premise Passphrase keyboard appears, retrieve 
the Premise Passphrase for the current SMA Gateway 
(the Premise Passphrase is unique to the current SMA 
Gateway and was generated upon Activation): 

Login to the Management Portal via the Internet. 

From the Dashboard, use the Start a Customer Search 
tool to search for the current customer’s account. 

When the Customer Search Results screen appears, 
find the customer in the listed query results and click 
the customer’s Account Number. The Account Details 
of the current customer appears. 

Find the section 

TouchScreen Premise Pass Phrase

When the Premise Passphrase for the current SMA 
Gateway appears, enter Premise Passphrase and click 

Done

. The currently installed sensors/security zones 

appear.  

D.

 

Touch the zone you want to delete and follow the 
instructions provided by the SMA Gateway to delete the 
sensor and security zone from the current SMA system. 
 

9   

5B

Troubleshooting 

If you encounter a problem with the SMCDW01-Z: 

 

Verify that a new battery has been properly installed 
(see step 1, “Pre-installation Guidelines.” 

 

Confirm that the SMCDW01-Z has been defaulted 

 

Be sure the unlocated SMCDW01-Z is in working order if 
only one multiple sensor failed. 

 

Test signal strength between the sensor and SMA 
Gateway (see Step 3, “Test the Signal Strength”). 

 

Mount the SMCDW01-Z to a door or window. 

 

Use the procedure in step 3 to check the signal strength 
between the SMCDW01-Z and SMA Gateway again. 

Compliances 

 

FCC Notice: 

This device has been designed, constructed, and tested with 

for compliance with FCC Rules that regulate intentional and unintentional 
radiators. As the user of this device, you are not permitted to make any 
alterations or modifications to this equipment or to use it in any way that is 
inconsistent with the information described in this quick-start guide, 
without the express written permission of SMC Networks. Doing so will void 
your warranty to operate this equipment.

 

 
This device complies with Part 15 of the FCC rules. Operation of this device 
is subject to the following two conditions:  

1) This device may not cause harmful interference, and  

2) This device must accept any interference received, including 
interference that may cause undesired operation. 

The SMCDW01-Z contains FCCID:JI5-SMCDW01Z and ICID:4137A-SMCDW01Z. 
The “IC” designation preceding the radio certification number indicates 
that this device complies with the Industry of Canada specifications. 

ETL Notice

: This device complies with all ETL and ETLC safety 

requirements. 
 

UL and ULC Notices