background image

C

OMPLIANCES

iv

EC Conformance Declaration - Class A

SMC contact for these products in Europe is:

SMC Networks Europe,
Edificio Conata II,
Calle Fructuós Gelabert 6-8, 2

o

, 4

a

,

08970 - Sant Joan Despí,
Barcelona, Spain.

This information technology equipment complies with the requirements of the 
Council Directive 89/336/EEC on the Approximation of the laws of the Member 
States relating to Electromagnetic Compatibility and 73/23/EEC for electrical 
equipment used within certain voltage limits and the Amendment Directive 93/68/
EEC. For the evaluation of the compliance with these Directives, the following 
standards were applied: 

RFI Emission:

• Limit class A according to EN 55022:1998

• Limit class A for harmonic current emission according to 

EN 61000-3-2/1995

• Limitation of voltage fluctuation and flicker in low-voltage 

supply system according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

• Electrostatic Discharge according to EN 61000-4-2:1995 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

• Radio-frequency electromagnetic field according to 

EN 61000-4-3:1996 
(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

• Electrical fast transient/burst according to EN 61000-4-4:1995 

(AC/DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

• Surge immunity test according to EN 61000-4-5:1995 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

• Immunity to conducted disturbances, Induced by 

radio-frequency fields: EN 61000-4-6:1996 
(0.15 - 80 MHz with 1 kHz AM 80% Modulation: 3 V/m)

• Power frequency magnetic field immunity test according to 

EN 61000-4-8:1993 
(1 A/m at frequency 50 Hz)

• Voltage dips, short interruptions and voltage variations 

immunity test according to EN 61000-4-11:1994 
(>95% Reduction @10 ms, 30% Reduction @500 ms, >95% 
Reduction @5000 ms)

LVD:

• EN 60950 (A1/1992; A2/1993; A3/1993; A4/1995; A11/1997)

Summary of Contents for SMC6724L2GLSC

Page 1: ...TigerSwitch Module Gigabit Uplink Module for TigerSwitch 10 100 Switches User Guide SMC6724L2GSSC SMC6724L2GLSC...

Page 2: ......

Page 3: ...6 Hughes Irvine CA 92618 Phone 949 707 2400 TigerSwitch Module User Guide From SMC s Tiger line of feature rich workgroup LAN solutions August 2001 Pub 150547 102 R02...

Page 4: ...nse is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2001 by SMC Networks Inc 6 Hugh...

Page 5: ...that incorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of dis...

Page 6: ...IDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUN...

Page 7: ...rference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference You are cautioned that changes or modifications not expressly...

Page 8: ...low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995 Contact Discharge 4 kV Air D...

Page 9: ...ions Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NM...

Page 10: ...COMPLIANCES vi...

Page 11: ...lling the Module 3 Equipment Checklist 3 Handling the Modules 4 Instructions 4 Troubleshooting 7 Cables 9 Cable Specifications 9 Specifications 11 TigerSwitch Gigabit Uplink Modules 11 General 11 SMC6...

Page 12: ...TABLE OF CONTENTS viii...

Page 13: ...be connected to a site up to 5 km 16 404 ft away Gigabit Port LEDs The switch s front panel provides LEDs that indicate the presence of modules installed in the rear panel slots Port status LEDs are...

Page 14: ...DESCRIPTION OF HARDWARE 2...

Page 15: ...our distributor for advice on newly released switches that may be designed for use with this module The TigerSwitch 10 100 Extender Module is field installable Just follow the instructions below Equip...

Page 16: ...n appropriate anti static packaging Instructions CAUTION The switch must be powered off before installing or replacing any module 1 Power off the switch Disconnect the AC power cord from the switch If...

Page 17: ...ve the module replace the faceplate to prevent dust and debris from entering the unit and to maintain proper air flow 5 Insert the new module into the switch Holding the new module with the text on th...

Page 18: ...r further information 8 Power on the switch Reconnect the previously removed power sources to the switch Check the switch s front panel LED indicators to ensure that the module is operating correctly...

Page 19: ...they are properly engaged When attaching fiber cable to an SC type port be sure the plug clicks into place to ensure that it is properly seated If you are using fiber optic cable with an ST type conn...

Page 20: ...TROUBLESHOOTING 8...

Page 21: ...iber MMF See the following table SC or ST 1000BASE LX 9 125 micron core single mode fiber SMF 5 km 16 404 ft SC 1000BASE SX Fiber Specifications Fiber Diameter Fiber Bandwidth Cable Length Range 62 5...

Page 22: ...CABLES 10...

Page 23: ...ation Rate 1000 Mbps LED Indicators Status one per module Size 7 2 x 9 1 x 2 4 cm 2 83 x 3 58 x 0 94 in Power Consumption 4 W maximum Temperature Operating 0 to 50 C 32 to 122 F Storage 40 to 70 C 40...

Page 24: ...3548 1995 Class A Immunity EN 61000 4 2 3 4 5 6 8 11 Warranty Limited Lifetime SMC6724L2GSSC Ports 1 1000BASE SX Network Interface SC connector 62 5 125 or 50 125 micron multimode fiber cable SMC6724...

Page 25: ...C6724L2GSSC SC ST converter SMC6724L2GLSC Gigabit Module with one 1000BASE LX single mode port SC type connector SMC6724L2GT Gigabit module with one 1000BASE T port RJ 45 connector SMC6724L2FSSC Exten...

Page 26: ...ORDERING INFORMATION 14...

Page 27: ......

Page 28: ...49 707 2460 Spain 34 93 477 4920 Fax 34 93 477 3774 UK 44 0 1188 748700 Fax 44 0 1189 748701 Southern Europe 33 1 41 18 68 68 Fax 33 1 41 18 68 69 Central Eastern Europe 49 0 89 92861 200 Fax 49 0 89...