SMC Networks SFDA Series Manual Download Page 4

Selection

Warning

1.  Do not select a model exceeding specifi cation ranges and 

carefully consider the purpose of use, required specifi ca-
tions, and operating conditions, such as fl uid, pressure, 
fl ow rate, nominal fi ltration rating, and environment.

2.  The product is not certifi ed under the High Pressure 

Gas Safety law, so for nitrogen, its maximum 
operating pressure will be 0.99 MPa (gauge pressure).

3.  The product is provided for use in manufacturing indus-

tries. Contact us beforehand if the product will be used 
in an application such as a caisson shield, breathing, 
food (other than air-blowing), and/or medical treatment 
that affects the human body directly or indirectly.

4.  The product removes and reduces bacteria contained in 

the compressed air. Bacterial removal refers to the effect 
of reducing bacteria. It does not mean that all bacteria are 
eliminated. Not for eliminating the virus.
LRV (Log Reduction Value) is a mathematical representa-
tion that was obtained from the test (evaluation based on 
JIS K 3835) using test bacteria (Brevundimonas diminuta).

5.  The product is assembled and packaged in a clean room 

environment but does not adhere to the sanitation control 
procedures for the use in food and medical industries.

6.  If the compressed air includes ozone, do not use it since 

it may damage the product or cause malfunction.

Caution on Installation

Caution

1.  If the pressure difference (pressure drop) between 

the inlet and the outlet exceeds 0.1 MPa, it can 
cause damage to the product.

2.  Do not install the product in a place where it can be 

affected by a pulsation (including surge pressure) 
of over 0.1 MPa.

3.  Use caution regarding the particles that may be 

emitted from the outlet side of pneumatic equip-
ment.

The installation of pneumatic equipment on the outlet side can 
deteriorate the cleanliness because a particle will be 
generated from the equipment.
The mounting position of the pneumatic equipment needs to 
be considered.

4.  Set the air fl ow capacity with an initial pressure drop 

of 0.03 MPa or less. If the initial pressure drop is set 
to be high, its life will be shortened due to clogging.

5.  Generally, the following pollutant particles are 

contained in compressed air.

[Pollutant particle substances contained in the 
 compressed air]

 · Moisture (drainage)
 · Dusts and particles which are in the surrounding air
 · Deteriorated oil which is discharged from the compressor
 · Solid foreign matter such as rust and/or oil in the piping

1)  The SFDA series is not compatible with compressed air 

which contains fl uids such as water and/or oil.

2)  Install a dryer (IDF, IDG, ID series), line fi lter (AFF-D 

series), mist separator (AM series), micro mist separator 
(AMD series), super mist separator (AME series), or odor 
removal fi lter (AMF series), etc., for the source of the air for 
the SFDA series.

6.  Using with a fl ow-rate much higher than its 

specifi cation could lead to exceeding the differential 
pressure the product can resist.

Use the product within its specifi cations. Also, take care about 
the replacement period of the product, taking into 
consideration that the differential pressure of the fi lter will 
increase over time.

Mounting

Warning

1. Operation manual

Install the products and operate them only after reading the 
operation manual carefully and understanding its contents. Also, 
keep the manual where it can be referred to as necessary.

2. Flushing

Flush the piping line before using the product for the fi rst time 
and after it has been replaced. Also, if piping, etc., is to be 
connected, fl ush (air blow) before using this product for the 
fi rst time and after the element has been replaced in order to 
reduce the effects of the dust generated from the connection, 
etc. Flushing the line is also required to eliminate 
contamination resulting from the installation of piping lines. 
Therefore, be sure to fl ush the line before running the system. 
Make sure all mounting parts are secure before use.

Caution

1.  Connect the piping in accordance with the flow 

direction marked on the case.

If connected in reverse, the element could break.

2.  Mounting orientation does not affect the performance.

Be sure to read this before handling the products. Refer to the back cover for safety instructions. 
For air preparation equipment precautions, refer to the “Handling Precautions for SMC Products” 
and the “Operation Manual” on the SMC website: https://www.smcworld.com

SFDA 

Series

Specifi c Product Precautions 1

3

Summary of Contents for SFDA Series

Page 1: ...cation for flow path 2 Parts in contact with fluid Resin Rubber Designed for use in applications to HACCP principles and FSSC22000 standards Captures bacteria in the compressed air 1 LRV Log Reduction...

Page 2: ...es 0 1 MPa Materials of parts in contact with fluid Metal parts Stainless steel Resin Rubber parts Materials compliant with FDA Food Sanitation Law Lubrication oil NSF H1 grade Weight Port size 1 4 45...

Page 3: ...e SFDA203 02 03 Component Parts Replacement Parts w q r r t e Description Part no Set description Element set SFDA EL200 ert With 3 O rings Bracket SFD BR200 Material Stainless steel 304 No Descriptio...

Page 4: ...due to clogging 5 Generally the following pollutant particles are contained in compressed air Pollutant particle substances contained in the compressed air Moisture drainage Dusts and particles which...

Page 5: ...locations with high humidity or large amounts of dust 2 When the product is used for blowing use caution to prevent the work from being damaged by entrained air from the surrounding area If compressed...

Page 6: ......

Page 7: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one countr...

Page 8: ...e smc hu Ireland 353 0 14039000 www smcautomation ie sales smcautomation ie Italy 39 03990691 www smcitalia it mailbox smcitalia it Latvia 371 67817700 www smc lv info smc lv Lithuania 370 5 2308118 w...

Reviews: