![SMC Networks PTE-300-V Instruction Manual Download Page 45](http://html1.mh-extra.com/html/smc-networks/pte-300-v/pte-300-v_instruction-manual_1300980045.webp)
PTE-300-V
Sheet 44
c) One of the output channels is available to be configured as
Master
of the other two, which can
be configured as
Slave
or
Independent
. Every change made in the
Master
channel will be
effective in the
Slave
channels, at all levels.
5.3.
EXTERNAL REFERENCE INPUT
The unit has available an external reference input, capable to receive voltage or current signals from
any external source in the following ranges:
•
Voltage input: between 5 and 300 V.
•
Current input: between 0.1 and 25 A.
•
Frequency range: between 40 and 70 Hz.
5.4.
SIGNAL MONITORS
The unit has a signal monitor that can work with dry contacts and live voltage signals from 5 to 250 V
ac or dc.
5.5.
AVAILABLE REFERENCES
The equipment power output has the possibility to be referenced to the following synchronizing
sources:
•
Internal Frequency Generator.
•
Communication BUS.
•
Voltage supply of the unit.
•
External reference Input.
5.6.
CONTAINER
The unit is contained in aluminum case that, when closed, offers an IP-65 protection.