![SMC Networks MXQ12 Series Operation Manual Download Page 13](http://html1.mh-extra.com/html/smc-networks/mxq12-series/mxq12-series_operation-manual_1299676013.webp)
13
2-8 Handling of optional functions
●With end lock
!
Caution
①
The weight of the workpiece shall be maximum load mass or less.
Load exceeding the maximum load mass can cause locking failure or the damage of the end lock
mechanism.
Maximum load mass (kg)
Model
Without
adjuster
Optional adjuster
Internal rubber
cushion
Rubber stopper
With bumper
Metal stopper
Shock absorber
RJ
MXQ6(A)
0.6
0.6
-
0.6
MXQ8(A,C)
1
1
1
1
MXQ12(A,C)
2
2
2
1
MXQ16(A)
4
4
4
2.5
MXQ20(A)
6
6
6
5
MXQ25(A)
9
9
9
5.5
②
Use 2 position 4/5 port solenoid valve.
Control circuit such as exhaust center 3 position valve in
which both ports exhaust, operation failure can result.
③
Connect the meter-out speed controller to the cylinder.
Operation without meter-in control or speed controller
can cause operation failure.
④
Release the pressure when performing manual release
of the end lock.If the pressure remains
when manual release is performed,
damage to the workpiece may occur due to sudden action.
How to release the end lock manual
※
Confirm no pressure is applied before the work.
①
Push down the lever
②
Slide the table in the direction of the arrow.
Use
Recommended Air
Pressure Circuit.
Air Slide Table